Electrical Connection

Connect the evaluation unit with the control panel (see connection diagram). Then connect the probe /
sensor and the function earth BE with the evaluation unit.
Evaluation unit
KFA-5-1-...-N-A-...
KSLA-5-1-...-N-A-...
KXA-5-1-...-N-A-...
KFA-5-1-...-P-A-...
KSLA-5-1-...-P-A-...
KXA-5-1-...-P-A-...
KFA-5-2-...-N-A-...
KSLA-5-2-...-N-A-...
KXA-5-2-...-N-A-...
KFA-5-2-...-P-A-...
KSLA-5-2-...-P-A-...
KXA-5-2-...-P-A-...
Please take note that the use of a DC / DC-transducer calls briefly for a higher current than
the operating current when initially switching on the equipment. Therefore the power supply
must have enough low-impedance!
Output function
NPN, Antivalent
A1 = Normally open
A2 = Normally closed
PNP, Antivalent
A1 = Normally open
A2 = Normally closed
NPN, Antivalent
A1 = Normally open
A2 = Normally closed
each channel
CH1 = channel 1
CH2 = channel 2
PNP, Antivalent
A1 = Normally open
A2 = Normally closed
each channel
CH1 = channel 1
CH2 = channel 2
Connection diagram
+ Teach mode
- Operating mode
+ Teach mode
- Operating mode
+ Teach mode
- Operating mode
+ Teach mode
- Operating mode
19