Copying The Time Program; Copying To Further Devices; Controller Operating Parameters - Honeywell Home TheraPro HR90 Manual Del Usuario

Electronic radiator controller
Ocultar thumbs Ver también para TheraPro HR90:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

5. For the further setpoints also select the tem-
perature as well as the beginning and end of the
setpoint as described in Steps 1 to 5.
NOTES:
• A setpoint is not saved until the temperature,
beginning and end have been confirmed with the
OK button.
• If a setpoint is not required, select the setting --.-
Deleting a setpoint
When a setpoint is not required, select the
temperature setting --.- and confirm with OK.
NOTE: The first setpoint cannot be deleted.
Adding a setpoint
1. Turn the adjustment dial until add new is dis-
played and confirm with OK.
The temperature display flashes.
2. Use the adjustment dial to select the desired
temperature (Comfort temperature 1, 2 or Set-
back temperature) for the new setpoint and con-
firm with OK.
The beginning of the new setpoint flashes.
3. Use the adjustment dial to set the desired begin-
ning for the new setpoint and confirm with OK.
The end of the desired setpoint flashes.
4. Use the adjustment dial to set the desired end of
the new setpoint and confirm with OK.
NOTE: Add new is only displayed when less than 6
setpoints are programmed.

Copying the time program

If several HR90 radiator controllers are to operate with
the same time program, the time program only has to
be created at one device (master) and can then be
copied to further radiator controllers.
NOTE: The ACC90 cable is required to copy the time
program.
IMPORTANT
The ACC90 cable must be used to copy pro-
grams. Use of any other cable may damage the
device.
• 2 x Micro B mini-plugs
• 0.5 m long
• Not included in the scope of delivery
1
M35645
3
2
M35646
1. Remove the side cover from all the radiator con-
trollers.
2. Connect the master (with time program) and a
further HR90 radiator controller using the
ACC90 cable.
3. Press the buttons AUTO and OK at both devices
simultaneously for 4 seconds.
Com mode is displayed in the display of both
devices.
4. Press the PROG button at the master.
Master is displayed on the master and then
tramsmit.
Com mode is displayed on the other device and
then receive.
The time program is copied.
5. The copying process is completed when finished
is displayed at both devices.
6. After 2 seconds the device with the copied time
program changes to the automatic mode, com
mode is displayed again at the master.
7. Disconnect the ACC90 cable from the device
with the copied time program.
NOTE: If there are no activities at one of the two radi-
ator controllers for 4 minutes, they change
automatically to automatic mode.

Copying to further devices

1. Insert the ACC90 cable into the next device.
2. Press the buttons AUTO and OK at the next
device simultaneously for 4 seconds.
Com mode is displayed at this device.
Com mode is displayed at the master.
3. Press the PROG button at the master.
The further copying procedure is the same as
described at the first copying process.
Terminating copying
After the last copying process has been completed:
1. Press the AUTO button at the master in order to
change to the automatic mode.
2. Remove the ACC90 cable and put the side cover
back on at all the devices.
9. CONTROLLER
OPERATING PARAMETERS
Overview
If required, the 19 basic settings (parameters) can be
adjusted.
Factory settings are in bold text.
7
THERAPRO HR90
33-00084EFS—03

Publicidad

Tabla de contenido
loading

Tabla de contenido