Installation and Maintenance Instructions
4.
Make sure the insulation of the supply lead is flush with the
connector. If stranded wire is used, be sure that there are no loose
strands outside the connector plug that could touch the adjacent
lead and cause a short circuit.
5.
Tighten the terminal screws to secure the wires in the connector.
6.
Place the outer dome back into position and reinstall the two
outer dome screws
7.
Apply power to verify the light operates properly.
Safety Message to Maintenance Personnel
Listed below are some important safety instructions and precautions
you should follow:
•
Read and understand all instructions before operating this system.
•
Any maintenance to the light system must be done with power
turned off.
•
Any maintenance to the light system must be performed by a
trained electrician who is thoroughly familiar with all applicable
national and local codes in the country of use.
•
If the dome is damaged in any way, it should be replaced.
•
Do not connect this light to the system when power is on.
•
Never alter the unit in any manner. Safety may be compromised
if additional openings or other alterations are made to the internal
components or housing.
•
The nameplate should NOT be obscured, as it contains cautionary
and/or other information of importance to maintenance personnel.
Ensure the nameplate remains readable if the housing exterior is
painted.
•
After performing any maintenance, test the light system to ensure
that it is operating properly.
Electraflash
8