Description of the parameters, and their limitations.
As a useful guide, we have listed for you in Table below, the parameters, their functions
and their limits. The comments will draw your attention to other relevant details.
Parameter
Function
Limits
Comments
Parameter
Function
Limits
Comments
Parameter
Function
Limits
Comments 1. Vacuum pump will start pumping out the air before the DRY TIME
2. If DRY TIME without vacuum required, VACUUM START temperature
Parameter
Function
Limits
Comments
Parameter
Function
Limits
Comments 1. Must not be less than "VACUUM OFF" temperature. (When a vacuum
2. One of the parameters which have to be included in order for a
FOCUS 4010/HT Dental Porcelain Furnace
START. TEMP
The starting temperature of the program. When it is reached the
cycle will begin.
100C to 450C
One of the parameters, which have to be included in order for a
program to run.
UP TIME
The time required to raise the platform from lowest position until
the muffle is closed.
0 to 30:00 Min
During UP TIME the platform rises in four progressive stages.
DRY TIME
The final stage of the UP TIME during which the muffle is closed
and the temperature does not rise for the defined duration.
0 to 30 minutes.
countdown begins.
value should be 5C higher than START TEMP.
HEAT RATE
The rate in C or F at which the temperature rises from START
TEMP to HIGH TEMP and from HIGH TEMP to FINAL TEMP.
10 C to 100 C
One of the parameters which have to be included in order for a
program to run..
HIGH TEMP
The temperature to be reached at the end of the HEAT RATE or
intermediate temperature when the value of the FINAL TEMP is
higher
100C to 1100C in normal
100C to 1180C in HT
is included in the program).
program to run.
Page 14
Manual version 20.08.2015