Whirlpool SPIW409/2 Instrucciones Para El Uso página 49

Ocultar thumbs Ver también para SPIW409/2:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 108
Select the best location
Location for Installing Indoor Unit
• Where there is no obstacle near the air outlet
and air can be easily blown to every corner of
room.
• Where piping and wall hole can be easily
arranged.
• Observe the required distance from ceiling and
wall according to the installation diagram.
• Where the air filter can easily be removed.
• Keep the unit and remote control 1m or more
from television, radio etc.
• To prevent the effects of a fluorescent lamp,
keep the unit as far as possible from it.
• Do not put anything near the air inlet that could
obstruct it.
• In a place that can bear the weight and will not
increase operating noise and vibrations.
• The indoor unit is not suitable to be installed in
areas used for laundry.
Location for Installing Outdoor Unit
• Install in a convenient and well-ventilated place.
• Avoid installing it where flammable gas could
leak.
• Observe the required distance from the wall
according to the installation diagram.
• The distance between Indoor and outdoor unit
should be 3 meters and can go up to maximum
15 meters with additional refrigerant charge.
• Do not install the outdoor unit in a dirty or
greasy place, near a vulcanization gas exit.
• Avoid installing it at the roadside where it could
be soiled with muddy water.
• A fixed base where operating noise will not
increase.
• Where the air outlet is not obstructed.
• The installation position shall be able to
withstand the weight and vibration of the
outdoor unit and ensure safe installation;
• Where drained water does not become any
problem.
• Install the outdoor unit at a place where the air
discharged and the operation noise would not
disturb your neighbours.
Model
Standard tubing
9K/12K/18K
24K
Limit of Tubing
Length (m)
Length (m)
5
5
Indoor unit
Pipe length is
3~15 meters
Indoor unit
Limit of Elevation
Difference H (m)
15
5
15
5
49
Pipe length is
3~15 meters
Outdoor unit
Outdoor unit
Required extra
refrigerant when
the connecting
tube over 5m
(g/m)
20
30

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Spiw412/2Spiw418/2Spiw422/2

Tabla de contenido