Maintenance - Scheppach AB1600 Traducción De La Instrucción De Original

Ocultar thumbs Ver también para AB1600:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 288
• The product is intended solely for use at
connection points that
a) do not exceed a maximum permit-
ted supply impedance "Zmax", or
b) have a continuous current-carrying
capacity of the mains of at least 100
A per phase.
• As the user, you are required to ensure,
in consultation with your electric power
company if necessary, that the connec-
tion point at which you wish to operate
the product meets one of the two re-
quirements, a) or b), named above..
Connections and repairs of electrical
equipment may only be carried out by an
electrician.
Please provide the following information
in the event of any enquiries:
• Type of current for the motor
• Machine data - type plate
• Motor data - type plate

13. Maintenance

If personnel qualified for unusual mainte-
nance tasks or repairs must be obtained
during of after the warranty period, please
always contact a service point recom-
mended by us or contact the manufactur-
er.
• Only perform repair, maintenance and
cleaning work as well as the correction
of malfunctions with the drive switched
off as a basic rule.
• All protective and safety equipment
must be reassembled immediately after
repair, maintenance is completed.
 www.scheppach.com /  service@scheppach.com /  +(49)-08223-4002-99 /  +(49)-08223-4002-58
Cleaning
m CAUTION! Disconnect the mains
plug.
• Clean the machine each time after com-
pleting work.
• The machine should be cleaned regu-
larly to remove dust and dirt.
• Keep safety devices, air vents and the
motor housing as dust and dirt-free as
possible.
• Clean the device with a clean cloth, or
blow it out with compressed air at low
pressure.
• All moving parts are to be re-greased at
periodic intervals.
• Do not use detergents or solvents as
these might damage the plastic parts of
the device. Make sure that no water can
get inside the device.
Carbon brushes
In case of excessive sparking, have the
carbon brushes checked by a qualified
electrician.
m CAUTION! The carbon brushes should
be replaced only by a qualified electrician.
Check the oil level
The oil level should be checked before
each use of the device.
Place the device with the tool holder in the
down position on the floor. The oil must be
at least 4 mm above the bottom edge of
the sight glass. Refill oil, if required.
Oil change (Fig. E)
The oil should be changed after about 40-
50 hours of operation.
Recommended oil: 30 ml SAE 15W/40 or
similar.
GB | 45

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

59082019015908201905

Tabla de contenido