Range
200 Ω
2 kΩ
20 kΩ
200 kΩ
2 MΩ
20 MΩ
Protection against overchange: 220VDC or AC rms for all ranges.
Open circuit voltage: 750 mv.
Humidity: 0-75%, 0-35°C en 2 MΩ y 20 MΩ, 0-90%, 0-35°C in any other range.

Testing diodes

1. Connect the red testing probe to the jack signaled "V/Ω" and the black testing
probe to the jack signaled "COM".
2. Select the function
• If one of the testing probes is not connected to the circuit, the LCD screen will
display "1", indicating an over range.
• When you use this function, through the testing element circulates a 1 mA
current, approximately.
10
10
Resolution
0.1 Ω
1 Ω
10 Ω
100 Ω
1 kΩ
10 kΩ
and realize the measurements.
Accuracy
± (0.5% ± 1 digit)
± (0.5% ± 1 digit)
± (0.5% ± 1 digit)
± (0.5% ± 1 digit)
± (1.0% ± 2 digits)