D.S.) Safety device (Photocells):
The control unit allows the connection and the control of
Photocells, Tyre sensors (NC).
- Input DS (NC)
During opening the operation of photocells is not contem-
plated, During closing it causes the reversal movement.
Forced Closing:
In case of damage or malfunction of the Safety Device
(Input DS), the electronic panel automatically does a vol-
untary forced closing of The frame.
Using both the memorized radio control (led CODE on) and
the low tension button, you can do the forced closing In the
following way: to keep sending the command for a higher
time Of 5 seconds, then the frame starts the closing till
the run-end or till The end of motor time, but only having
pushing the move command.
With closed frame, the electronic panel turns to the nor-
mal function.
Activation/Deactivation Alarm System
(Led CODE ALARM):
By manufacturing arragement, the electronic panel starts
(15 Seconds after the end of the programmed motor time)
and Automatically cuts (immediately) the Alarm system of
the close or Open frame. Using the memorized radio con-
trol (led CODE ALARM on), you can start or cut the Alarm
system as you want. Avoiding false activations or deacti-
vations, the button of the radio Control has to be pushed
for at least 5 seconds. Then the flashing Light (on for 3
seconds) and the Alarm light (10 rapid flashes) will Show
the choosen movement.
Z1 - Z2 ) Alarm Devices (zone 1 and zone 2):
It is possible to connect and supply 2 Alarm sensors (NC).
They can immediately activate the siren and the OUT AUX
Contact (NC).
T) Safety Device (Tampere):
It is possible to do the anti-split connection (Tampere) of
the siren and all the other alarm sensors (NC).
This can do the activation of the siren and the OUT AUX
contact (NC), even if the alarm system was cut by the
CODE ALARM Command.
Important: in case of maintenance, in order to cut the
control of The Tampere input, it will be necessary to swich
to Installer Mode (see the connected paragraph) before
every operation On the Alarm system.
Output (Sirens) from J1:
It is possible to connect standard sirens with supply for bat-
tery charge upkeeping. With siren on, the battery supply is
stopped .
Or this can be caused by the related command (positive to
miss Default J1=1-2 or negative to miss J1=2-3).
Auxiliary Alarm Output (OUT AUX) from J2:
The electronic panel has an OUT AUX output (normally close
NC default J2=2-3 or normally open NA J2=1-2) for the
Connection of accessories or other present alarm systems.
The activation of the output will be simultaneous to the ac-
tivation Of the alarm till its switching off.
Light Alarm System:
It is possible to connect a light 12Vdc 2W max. to know the
alarm Status of the automation. Light off: alarm off; light on:
10 rapid Flashes for activations and disactivations and rapid
light with Lasting alarm for no electrical line, wireless sensor
out of Batteries or alarm on (also with time-signal mode).
Buffer Battery 12V 2,7Ah max:
It is possible to connect a buffer battery to make in work only
the Alarm system, also with electrical line missing. Moreover
it has An incorporated battery charger 13,8V (both for buffer
battery And the one in the alarm siren).
PROGRAMMING:
SEL button: selects the type of function to be memorised.
The selection is indicated by a flashing LED.
By repeatedly pressing the button it is possible to choose
the Desired function. The selection will remain active for 10
seconds indicated by a flashing LED. If no other operations
are executed during this period, the control board will return
to its previous state.
SET button: programs the information relative the type of
function previously selected with the SEL button.
IMPORTANTE the function of the SET button can also be
replaced With radio control if it was programmed before
(led CODE on).
MAIN MENU'
The electronic panel is supplied with the possibility to se-
lect some important functions.
________________ MAIN MENU' ________________
LED Reference
LED Off
1) CODE
No code
2) CODE ALARM No code
3) LAMP./CORT. Flashing Lamp
4) T. MOT.
Programmed 30''
5) T. PAUSA.
No automatic close
1) CODE: (Programming of radio controls)
Programming of radio control for frame:
The programming of transmission codes of radio control for
the Frame operation is done in the following way: push SEL
10
LED On
Device activated
Device activated
Courtesy Light
Programmed delay
With automatic close