Status Meaning
Recycling mode
Water supply mode
Vacuum cleaner mode
3.5 Indicators
LED
Meaning
The water level is too low.
Fill the water and waste material container up to the MAX mark.
The water level is too high.
Switch to water supply mode until the indicator goes out.
No filter
Fit the filter bag fitted correctly.
4 Technical data
4.1 Technical data
Note
For details of the rated voltage, current, frequency and/or input power, please refer to the power tool's
country-specific type identification plate.
When powered by a generator or transformer, the generator or transformer's power output must be at least
twice the rated input power shown on the rating plate of the power tool. The operating voltage of the
transformer or generator must always be within +5% and -15% of the rated voltage of the power tool.
Protection class
Protection class
Weight in accordance with EPTA procedure 01/2003
Weight of the hose set
Operating temperature
Recommended temperature range for transport and stor-
age (without water in the container)
Suction hose length
Pressure hose length
Supply cord length
Container capacity
Water capacity
Volumetric flow rate (air)
Water flow rate
Water pressure
Printed: 12.06.2017 | Doc-Nr: PUB / 5306545 / 000 / 03
DD-WMS 100
I
IPX4
19.7 kg
1.8 kg
3 ℃ ... 40 ℃
−25 ℃ ... 70 ℃
5 m
5.1 m
4.8 m
32 ℓ
14 ℓ
≤ 74 ℓ/s
≤ 3 ℓ/min
≤ 7 bar
English
15