ENGLISH
EN
THE CONTROLS
The Vacuum/Accessory Switch
This switch is located on the left side of the control
panel. To turn the vacuum motor and pump motor on, press
the bottom of the switch. To turn the vacuum motor and
pump motor off, press the top of the switch.
The Spray/Brush Motor Switch
The spray/brush switch is located in the center of the
control handle. To turn on the spray/brush intermittently,
press the top of the switch and hold for the length of time
you want the floor spray/brush to run. To turn on the spray/
brush continuously, press the bottom of the switch. To turn
the spray/brush off, press the center of the switch.
NOTE: The vacuum/accessory switch must be in the "I"
position before spray will work.
The Vacuum Hose Connector
The vacuum hose connector is on the center right hand rear
of the machine.
The Solution Hose Connector
The solution hose connector is located in the center in the
rear of the machine. This connection is used to hook up
optional auxiliary floor tools.
Recovery Tank Drain
Remove hose from rear of machine. Place over drain and
open valve.
Rinse Tank Drain
Remove the hose from the rear of the machine. Place over
drain.
Brush Adjustment
Adjustment is located to the front right side of the machine.
Pull spring loaded pin and place in selected slot. If breaker
trips, move adjustment one slot higher.
Variable Pump Pressure (ix model only)
The control knob is located on the right side of the control
panel. The knob is divided into three operating ranges;
upholstery, interex and restoration. These range settings
are only suggested starting points. The control knob can be
adjusted clockwise to increase flow and pressure or counter
clockwise to decrease flow and pressure. If streaking
occurs, increase pressure setting.
Upholstery Setting:
Used for accessory tools.
Interex Setting:
Used with interim brush for
light extraction at medium
flow and pressure.
Restoration Setting: Used with restoration
brush for deep extraction
at high flow and pressure.
-6-
Clarke
®
Operator's Manual (EN) - Image 16 I/IX 120V