Installation Instructions – Prevail XL / USSL XL
INSTALLATION
This lighting fixture has been shipped complete with one
of several mounting options. Please follow the installation
instructions specific to the catalog part that you ordered.
Care must be taken not to set lighting fixture down on
optical lenses.
Pole Mount Arm
Tools Required
Ratchet, 3/4" socket, 3/4" wrench, 3/8" socket, #2 Phillips
head screw driver and torque wrench, drill.
1.
Pole mounting arm is designed for a square or round
pole. Round pole installation will require the mounting
arm break-away tabs to be removed. Grab tabs with
pliers and break-away as shown in (Figure 1). The
minimum pole diameter shall be: 3" . No isolators or
gasketing permissible between mounting surfaces.
2.
Mount the arm to the round or square pole using the
provided 1/2" x 1-3/4" long bolts, washers and nuts as
shown in (Figure 2). Torque bolts to 40 ft-lbs. (55 N-M).
3.
Fold fixture wire leads tightly towards fixture door when
sliding fixture on to mounting arm. Install the (3) 1/4-20
x 1" screws and tighten to 6 ft-lbs. Tighten the center
screw first as shown in (Figure 3).
4.
Make wire connections inside the mounting arm. Refer
to wire diagram for power connections. Connect the
supply wires to appropriate luminaire leads: (Figure 4)
•
Supply side ground wire to green luminaire lead.
•
Supply side neutral wire to white luminaire lead.
•
Supply side line voltage wire to black luminaire
lead.
5.
Install arm cover and tighten (2) Philips head screws to
20 in-lbs. (2.3 N-M). As shown in (Figure 5).
Ensure the luminaire supply leads do not get pinched
N
ote:
between cover and mounting arm as shown in
(Figure 3 & 5).
6.
If applicable, Install pole cap after completion of
luminaire installation and wiring.
For Round Pole Installations,
Break Away Tabs
Figure 1.
2
COOPER LIGHTING SOLUTIONS
9/16" (14.3mm)
Diameter Hole
And Slot
4-7/8˝
(124mm)
7/8˝
(22mm)
IB500018EN
Installation instructions
Split Washer
Washer
1/2" Bolt
Washer
Figure 2.
Figure 3.
Line (Black)
White Common
(Black 480V)
Green Ground
Figure 4.
Cover Plate
Screws.
Tighten To 20
in-lbs (2.3N-M)
Figure 5.
1/2" Nut
Install (3) 1/4-20 Screws And
Tighten to 30 in-lbs.
Black
White
(Black
480V)
Fixture
Green
Ground
Align Cover Tabs
With Arm Slots