ITEMS REQUIRED
(Purchase separately)
• Phillips screwdriver
• Flathead screwdriver
• Hammer
• Outdoor weatherproof silicone caulking
HOW IT WORKS
Your motion activated floodlight senses heat images from
objects such as people, large animals and automobile engines.
When motion is detected, the lights will automatically turn
on. Once motion has stopped, the lights will turn off after a
preselected time delay. Your motion activated floodlight may
also be used as a standard floodlight.
WARNINGS AND CAUTIONS
• Follow all instructions.
• For outdoor use only.
• cULus LISTED for wet locations.
• Connect fixture to a 120 volt, 60 Hz power source. Any other connection voids the warranty.
• Fixture must be mounted to a grounded recessed junction box marked for use in wet locations.
• Suitable for wall mount or eave mount only. NOT suitable for ground mount installation.
• Do not allow sensor head to touch light housing – maintain at least 1 inch space between
fixture and sensor.
• Keep away from flammable objects. Do not position fixture within two inches
of any combustible materials.
• Do not position lamp housing within two inches of house.
• Bulb gets HOT quickly!
• The bulb and fixture get extremely hot during use. Disconnect power and allow fixture to
cool before changing bulb or handling fixture.
• Fixture should be installed by persons with experience in household wiring or by a qualified
electrician. The electrical system, and the method of electrically connecting the fixture to it,
must be in accordance with the National Electrical Code and local building codes.
• Always replace bulb with the same wattage or lower wattage than included. Installing a
bulb of a higher wattage could create a fire hazard. Use of a higher wattage bulb will void
the warranty. (Maximum 150 watt halogen bulb.) To meet ENERGY STAR
maximum lamp wattage cannot exceed 250 watts.
• Never touch the bulb with your bare hands, as oil from your skin can cause premature
failure. Always handle bulb with gloves or a soft cloth.
• For proper operation and protection against damage, the motion
sensor head adjustment knobs must be facing the ground.
• For maximum bulb life, position fixture so the quartz halogen
bulb remains within 4 degrees of horizontal.
Questions? / ¿Preguntas ? 1-800-334-6871 ConsumerProducts@cooperlighting.com
PACKAGING CONTENTS / CONTENIDO DEL PAQUETE
A. Motion detector
B. 150 watt quartz halogen bulb
and light fixture
Detector de
movimiento y
artefacto de luz
180 degrees
®
requirements,
(preinstalled)
Foco halógeno de cuarzo de
150 vatios (preinstalado)
• Do not use this apparatus near water.
• Clean only with a dry cloth.
• Do not block any ventilation openings. Install in accordance with the manufacturer's
instructions.
• Do not install near any heat sources such as radiators, heat registers, stoves or other
apparatus (including amplifiers) that produce heat.
• Only use attachments/accessories specified by the manufacturer.
• Disassembly of your fixture will void the warranty.
• Your fixture is prewired and preassembled for easy installation.
Up to
• MINIMUM 90° C SUPPLY CONDUCTORS.
70 feet
• If lens is replaced, use only tempered safety glass of equal thickness per UL requirements.
• This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause undesired operation.
Under Part 15 of the FCC Rules, any changes or modifications to the motion detector
described in this instruction sheet that are not expressly approved by Cooper Lighting, LLC
could void the user's authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
- R eorient or relocate the receiving antenna.
- I ncrease the separation between the equipment and receiver.
- C onnect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
- C onsult the dealer or an experienced radio/TV technician for help.
WARNING: FCC Regulations state that any unauthorized changes or modifications
to this equipment not expressly approved by the manufacturer could void the user's
authorization to operate this equipment.
SAVE THESE INSTRUCTIONS.
FOR BEST RESULTS
• Install the motion sensor/transmitter 8-12 feet
above the ground. (Motion sensor is less sensitive
above 12 feet.)
• Locate motion sensor so motion moves across
detection zone (Fig. 1).
• Locate sensor away from heat producing sources to
prevent false triggering. Also be very careful not to
include objects such as windows, white walls and
water in the detection zone.
1
Instruction Manual / Instrucciones
C. Coverplate gasket
Junta de la placa
de cubierta
D. (2) #6 and (2) #8 mounting screws
(use the size that fits your junction box)
(2) Tornillos #6 y (2) tornillos #8 de montaje
(utilice el tamaño que mejor se adecue a
su caja de conexión)
E. (3) Wire nuts
(3) Tuercas
para alambre
Fig. 1

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Cooper Lighting MS80

  • Página 1 (use the size that fits your junction box) (2) Tornillos #6 y (2) tornillos #8 de montaje (utilice el tamaño que mejor se adecue a su caja de conexión) E. (3) Wire nuts (3) Tuercas MS80 (Bronze) para alambre MS80W (White) • Do not use this apparatus near water. ENGLISH • Clean only with a dry cloth.
  • Página 2 5. Replace glass lens cover. Insert and tighten the • Locate sensor away from moving objects such as trees, large shrubs and street traffic. screws that secure the glass lens cover. NOTE: Make sure your lamp housing is not positioned • Do not install more than one motion activated floodlight on one wall switch. within two inches of house. CAUTION: When replacing bulb in fixture, always MOUNTING AND WIRING YOUR FIXTURE replace with the same wattage bulb or a lower WARNING: Risk of electric shock. Disconnect wattage bulb. DO NOT replace with a bulb of power at fuse or circuit breaker before installing greater wattage than specified on the fixture.
  • Página 3: Artículos Necesarios

    ESPAÑOL Problem Cause / Solution Outdoor Light No power to the fixture. ARTÍCULOS NECESARIOS • Check if circuit breaker tripped. Does Not Come On With Motion • Confirm wall switch is ON. (se compran por separado) At Night Bulb is faulty. • Destornillador en cruz (Phillips) • Replace bulb. • Destornillador de cabeza plana Surrounding external ambient light is too bright. (If so, the unit may • Martillo think it is daytime.) • Calafateo de silicona resistente a la intemperie • Re-aim the head. CÓMO FUNCIONA • Relocate or reposition the unit away from the light.
  • Página 4: Para Obtener Los Mejores Resultados

    OPERACIÓN DEL ACCESORIO dispositivo digital Clase B, de acuerdo con la Parte 15 de las Reglas de la FCC. Estos límitesestán diseñados a fin de proveer una protección razonable contra la interferencia 1. Mueva el interruptor corredizo que se encuentra Fig. 5 dañina en una instalación residencial. Este equipo genera, usa y puede irradiar energía de en la parte inferior del sensor a “TEST”. Ajuste el radio frecuencia, y si no se instala y utiliza de acuerdo con las instrucciones, puede causar botón de sensibilidad a la posición media (hasta interferencia dañina en las comunicaciones de radio. Sin embargo, no se garantiza que no la mitad) (Fig. 5). vaya a producirse interferencia en una instalación en particular. Si este equipo efectivamente 2. Active la energía del portalámparas. Deje que el causa una interferencia dañina en la recepción de radio o televisión, lo que puede portalámpara se caliente aproximadamente 90 TEST 4 MIN. 12 MIN. determinarse apagándolo y encendiéndolo, se recomienda al usuario que trate de corregir SENSITIVITY segundos antes de hacer las pruebas. (Puede que la interferencia por medio de una o más de las siguientes medidas: las luces no se enciendan durante el período de - R eoriente o cambie de lugar la antena receptora. calentamiento.) - A umente la separación entre el equipo y el receptor. 3. Dirija la cabeza del sensor hacia el área de - C onecte el equipo en un tomacorriente que esté en un circuito difer ente de aquél al que detección deseada, manteniendo un ángulo se conecta el receptor.
  • Página 5: Seleccione La Función Deseada

    SELECCIONE LA FUNCIÓN DESEADA Problema Causa Posible/Acción Correctiva Modo de Adjuste de la perilla Como adjustar Las Luces Se La luz proveniente de la propia lámpara de la unidad está afectando funcionamiento de MODO interruptor electrico al sensor de movimiento. Encienden Y • Cambie la dirección de la lámpara. Se Apagan Ajuste Automático AUTO 4 MIN Mantenga la • Cambie la posición del sensor de movimiento. Continuamente (activado por movimiento) alimentación del Las luces deberán encenderse con el AUTO 12 MIN...