Pioneer SGY-PM910H2 Manual De Usuario página 29

Ocultar thumbs Ver también para SGY-PM910H2:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 162
■ Unable to switch to pedaling monitor mode.
Cause
You are not using cyclocomputer
SGX-CA500.
The version of the firmware of
SGX-CA500 is old.
■ Unable to switch to dual power meter mode.
Cause
You are not operating the right
transmitter push switch correctly.
More than 5 minutes have elapsed
after the battery was inserted.
You have paired with another
pedaling monitor sensor.
■ The power value of the pedaling monitor sensor is abnormal.
Cause
The battery terminal is dirty.
Battery
terminal
Solution
You cannot switch to the pedaling monitor mode if you
are using some other manufacturer's cyclocomputer. Use
SGX-CA500. For how to operate, refer to Page 15.
Update firmware to 20150501.02.43 or to a higher
version.
Solution
By pushing the push switch in the right transmitter for
more than 3 seconds, the LEDs on the right transmitter
blink green. When communication with the left transmitter
is enabled, the LEDs on the left and right transmitters
rapidly blink orange. As it blinks for 10 seconds, push the
switch again for more than 3 seconds to switch.
To operate by the push switch in the right transmitter,
insert the battery and do the above operation within 5
seconds after that.
When the LEDs on your left and right transmitters are
not blinking orange, it is likely that they are paired with
another pedaling monitor sensor by mistake. Move
somewhere away from other bicycles and do the above
operation again.
Solution
Use a dry cotton swab to wipe the battery terminal in the
transmitter taking care not to deform the terminal. Even if
it does not appear to be dirty, white dust may be lodged
in the battery terminal. Clean the terminal as the problem
will be improved if the dust is wiped out. Clean the
terminal regularly to ensure that the transmitter operates
stably.
EN
Troubleshooting
29

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Sgy-pm910hlSgy-pm910hr

Tabla de contenido