Features
• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Three lamp modes available: Normal, Soft, or Flash.
• Patented D
B
Timer.
®
ual
rite
• Photocell keeps the lighting off during daylight hours.
• LED indicates motion was sensed (day or night).
Requirements
• Not for use with fluorescent lights.
• The light control requires 120-volts AC.
• If you want to use Manual Mode, the control must be
wired through a switch.
• Install sensor in accordance with local codes.
OPERATION
Mode:
On-Time:
Test
5 Sec
Normal
1, 5, 20 min.
Manual
Until Dawn*
Accent
3, 6 Hr. to Dawn
* resets to Auto Mode at dawn.
Note: When first turned on wait about 1
the circuitry to calibrate.
Put ON-TIME switch on
the sensor bottom to
TEST and the D
B
®
ual
rite
switch OFF.
LAMP MODE
Put the LAMP MODE switch
in the Normal, Soft, or Flash
position.
© 2007 HeathCo LLC
All manuals and user guides at all-guides.com
Works:
Day
Night
x
/
minutes for
1
2
TEST
ON-TIME
D
B
ual
rite
TEST 1 5 20
Off 3 6 Dusk to
Dawn
LAMP MODE
NORMAL SOFT FLASH
Put the ON-TIME switch in the 1, 5,
or 20 minute position.
Manual mode only works at night be-
cause daylight returns the sensor to
AUTO.
Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.
Manual mode works only with the ON-
TIME switch in the 1, 5, or 20 position.
Mode Switching Summary
TEST
AUTO
MANUAL MODE
x
* If you get confused while switching modes, turn the power
x
off for one minute, then back on. After the calibration
x
time the control will be in the AUTO mode.
x
D
Light comes on half bright for selected time after dusk
(Off, 3 hr., 6 hr., until dawn). Selecting OFF disables this
feature. The motion sensing features will continue to work
as described in this manual. If motion is sensed, the light
turns on full bright for the ON-TIME (1, 5, or 20 minutes)
then returns to dim mode.
®
There are three lamp modes (light turn-on effects) avail-
able when motion is detected:
• NORMAL - Light instantly comes on.
• SOFT - Light starts dim and gradually increases to full
brightness. Light gradually dims to half-bright, pauses,
and then continues dimming to off when motion is no
longer detected and after selected ON-TIME.
• FLASH - Light flashes on then off twice before turning
on full brightness.
AUTO
ON-TIME
TEST 1 5 20
MANUAL MODE
1 Second OFF
Move ON-TIME Switch to 1,
5, or 20 minutes
Flip light switch off
for one second then
back on*
B
TIMER
®
ual
rite
LAMP MODES
then...
... back on.
598-1307-01