Operating instructions
Electronic display counter
CODIX 541, 542, 543 and 544
1. Description
CODIX 541
Please note: Read first chapter 1-4 of CODIX
544 and go on on page 4.
CODIX 542
Please note: Read first chapter 1-4 of CODIX
544 and go on on page 6.
CODIX 543
Please note: Read first chapter 1-4 of CODIX
544 and go on on page 7.
CODIX 544
CODIX 544 is a multipurpose device. Depend-
ing on the programmed basic function, the
device operates like
• the pulse counter CODIX 541 (see page 4) or
• the frequency meter CODIX 542 (see page 6) or
• the time meter CODIX 543 (see page 7)
t
1.1. Preface
Please read this instruction man-
ual entirely and carefully before
installation and start-up. Please
observe all warnings and advice,
both for your own safety and for
general plant safety. If the device
is not used in accordance with
this instruction manual, then
the intended protection can be
impaired.
2. Safety Instructions and Warnings
t
Please use the device only if its
technical condition is perfect. It
should be used only for its intend-
ed purpose. Please bear in mind
safety aspects and potential dan-
gers and adhere to the operating
instructions at all times.
Defective or damaged devices
should be disconnected from the
mains immediately and taken out
of operation.
The device shall not be opened.
Use the repair service of the
manufacturer.
www.kuebler.com
Only connect the device to the
electricity networks provided to
that purpose.
The safety of the system in which
the device is integrated is the
responsibility of the installer.
Disconnect all electricity networks
prior to any installation or mainte-
nance work.
Use exclusively cables approved
in your country and designed
for your temperature and power
ranges.
Installation and service work shall
be carried out exclusively by
qualified personnel.
The device must compulsorily be
protected with approved external
fuses. The value of these fuses
can be found in the technical
information.
This symbol is used on the de-
!
vice to remind of the existence of
dangers, which are referred to in
this manual.

2.1 Use according to the intended purpose

The counter detects and measures pulses,
times and frequencies up to max. 60 kHz and
offers a wide variety of different operating
modes. Use for any purpose over and beyond
this will be deemed as not in accordance with
its intended purpose and thus not complying
with the requirements.
The application area for this device lies in
industrial processes and controls, in the fields
of manufacturing lines for the metal, wood,
plastics, paper, glass, textile and other like
industries. Over-voltages at the terminals of
the device must be kept within the limits of
over-voltage Category II.
The device must only be operated when
mounted in a panel in the correct way and in
accordance with the section "Technical Data".