Bosch Rexroth SE312 Manual Del Usuario página 13

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 32
3 609 929 984/1.0 | SE312
4 Mounting Instructions
4.1
Exchanging the battery
1
3
2
4
Figure 1:
The tightening controller has a built-in bat-
tery-buffered RAM for storing the tightening
results. When power is turned off, the data is
saved due to the battery buffer. However, the
data will be lost in the "No batt" mode or
when the battery is fully discharged.
If the storage function is not needed, no bat-
tery is required. In this case, the jumper must
be moved from "Batt active" to "No batt"
(Fig. 2).
Figure 2:
If the battery has run down, an error message
is generated.
Electric Drives and Controls | Bosch Rexroth AG 13 /48
To exchange the battery, proceed as follows:
– Carry out data storage (when the battery
is exchanged, all data stored in the memo-
ry module are lost).
– Remove the used up battery. Slightly lift
the holder with a screwdriver (see illustra-
tion) and push out the battery. Remove the
battery with your fingers.
Under no circumstances remove
the battery with a conductive tool
(e.g. tweezers) – danger of short
circuit.
– Insert a new battery: the positive terminal
must face the holder (upward). To insert,
slightly lift the holder and push in the bat-
tery.
– Reset the real-time clock (operating pro-
gram).
The following is a list of recommended batter-
ies.
Com-
Designa-
ponent
tion
Lithium
BT1
cell 3 V
Table 2:
Manufactur-
Type
Comment
er/Supplier
SONY
CR2430 Lithium
battery 3 V,
SANYO
CR2430
Q ≥ 270 mAh
24.5x3 mm
VARTA
DL2430
DURACELL DL2430

Hide quick links:

Publicidad

Tabla de contenido
loading

Tabla de contenido