Installation
3. Remove the switch mounting screws from the motor.
See Figure 1.
NOTE: The new switch must be connected as shown
in either Figure 2A, or as in Figure 2B. Before dis-
connecting the old switch from the motor wires,
study and understand where the wires must go.
Proceed with Step 4.
4. Disconnect the switch leads from the motor.
5. Connect the wires as shown in Figure 2A or in Figure
2B.
NOTE: This switch is made with four quick connect
terminals. When a switch with leads is needed, use
the two leads provided in the switch kit.
Motor with Terminal Board
Grn
Top of
Motor
Blk
Wire Color Coding
Green ground
White
W
Grn
Blk
Black
Figure 2A
Motor with Access Hole
Motor access hole
Top of
Motor
Wire Color Coding
Green ground
White
W
Grn
Black, Brown, or Purple
Black
Bbp
Blk
Figure 2B
For parts or assistance, call Flotec Customer Service at
L1
Blk
W
Blk
L2
Bbp
Bbp
W
Blk
Grn
6. Attach the switch to the motor with the screws
provided.
7. Reposition the float rod through the switch eyelet
and reattach the upper rod stop.
8. Reconnect the power cord to the electrical outlet.
Lift the switch arm to the upper position and the unit
will start. Depress the switch arm to the lower posi-
tion and the unit will stop. See Figure 3.
Upper Position
(starts pump,
switch closed)
Lower Position
(stops pump,
switch open)
Figure 3
9. Check the switch operation by filling the sump with
water and observing the operation through one com-
plete cycle.
Risk of flooding. Failure to check installa-
tion with water in sump can lead to improper operation,
premature pump failure, and flooding.