Maximum Volumetric Flow Rate And Maximum Vacuum; Use Of Extension Cords - Hilti VC 30L Manual De Instrucciones Original

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 54
4.3

Maximum volumetric flow rate and maximum vacuum

Max. volume flow rate (turbine)
Max. volume flow rate (end of
hose)
Max. vacuum
Max. volume flow rate (turbine)
Max. volume flow rate (end of
hose)
Max. vacuum
4.4
Noise and vibration information (measured in accordance with EN 60335)
Emission sound pressure level (L
Uncertainty for the sound pressure level (K
Vibration emission value
5

Use of extension cords

Using extension cords
WARNING
A damaged supply cord presents a hazard! Do not touch the supply cord or extension cord if damaged
while working. Disconnect the supply cord plug from the power outlet.
▶ Check the appliance's supply cord at regular intervals and have it replaced by a qualified specialist if
found to be damaged.
Use only extension cords of a type approved for the application and with conductors of adequate gauge
(cross section). The power tool may otherwise suffer a drop in performance and the extension cord may
overheat.
Check the extension cord for damage at regular intervals.
Replace damaged extension cords.
When working outdoors, use only extension cords that are approved and correspondingly marked for
this application.
Information on recommended minimum conductor cross-sections and cable lengths is accessible via
a link, in the form of a QR code, at the end of this document.
6
Preparations at the workplace
CAUTION
Risk of injury! Inadvertent starting of the product.
▶ Unplug the supply cord before making adjustments to the power tool or before changing accessories.
Observe the safety instructions and warnings in this documentation and on the product.
7
Preparations at the workplace
7.1
Inserting dust bag (fleece)
1. Disconnect the supply cord plug from the power outlet.
2. Open the 2 container latches.
3. Lift the suction head off the waste material container.
4. If applicable, remove the full dust bag.
5. Seat the dust bag with adapter on the two positioning pins.
20
English
100 V
110 V
70 ℓ/s
71 ℓ/s
144 m³/h (40 ℓ/s)
144 m³/h (40 ℓ/s)
19.5 kPa (195 mbar)
21.5 kPa (215 mbar)
220 - 240 V (CH)
220 - 240 V (GB)
74 ℓ/s
74 ℓ/s
144 m³/h (40 ℓ/s)
144 m³/h (40 ℓ/s)
22.5 kPa (225 mbar)
22.5 kPa (225 mbar)
)
pA
)
pA
2
220 - 240 V
74 ℓ/s
144 m³/h (40 ℓ/s)
22.5 kPa (225 mbar)
240 V (NZ)
74 ℓ/s
144 m³/h (40 ℓ/s)
22.5 kPa (225 mbar)
76 dB(A)
2 dB(A)
< 2.5 m/s²