NSA7000
INSTALLATION INSTRUCTIONS FOR THE TECHNICIAN/FITTER
READ THIS INSTRUCTION SHEET AND THE SAFETY WARNING CAREFULLY BEFORE INSTALLING AND
SAVE IT FOR FUTURE USE
REPAIR AND REPLACEMENT
Do not attempt to repair the NSA7000 sensor. In case of improperly functioning control, contact the nearest Johnson Controls
representative, and speci-fy the desired product code number. When contacting the supplier for a replacement please state the
type/model number of the control located on the data plate or cover label.
IMPORTANT:
• Use this NSA7000 sensor only as an operating control. Where failure of malfunction of the NSA7000 sensor could lead to personal
injury or proper-ty damage to the controlled equipment or other property, additional precautions must be designed into the system.
Incorporate and maintain other devices such as supervisory or alarm systems or safety or limit controls intended to warn of, or
protect against, failure or malfunction of the NSA7000 sensor.
• Do not install this sensor in condensing, wet, or damp environment. Moisture may cause damage to the sensor.
• Do not remove PCB from the enclosure cover. Removing the PCB from the enclosure cover voids the product warranty.
• Make all wiring connection in accordance with local, nation, and regional regulations. Do not exceed the NSA7000 sensor
electrical ratings.
• Remove LCD plastic cover before use.
WARNING:
Disconnect power supply before making electrical connections. Contact with components carrying hazardous voltages can cause
electrical shock and may result in severe personal injury or death.
• Risk of Electrical Shock: Ground the device according to local, national, and regional regulations. Failure to ground the device
may result in electri-cal shock and severe personal injury and death.
• Risk of Electrical Shock and Property Damage: Insulate and secure each unused wire lead before applying power to the
device. Failure to insulate and secure each unused wire lead may result property damage, electrical shock, and severe personal
injury or death.
Setup and adjustment:
Press
button for 5 seconds, to get in parameter list, press
to change parameter value.
Item
Parameter
01
Display language
02
Units
03
Address
04
Temperature set point adjustment type
Humidity display
05
(only for NSA-FHR71X3-0)
06
Default display
07
Leaf symbol
08
Backlight time
09
Keypad Lock
10
Cooling trigger for leaf
11
Heating trigger for leaf
button to switch over setting items and use ∧ and ∨ button
Function
00: 中文; 01: English
o
00: ℃; 01:
F
00-16(199-215)
00=Set point; 01=W/C
00: enable
01: disable
00: room temperature
01: set point temperature
02: relative humidity
(only when Humidity display is available)
00: enable; 01: disable
05~60, reduce backlight after xx seconds
00: No lock
01: lock all keys
02: lock the key except occupancy
24~32℃
18~26℃
2
ENGLISH
®
Default
00
00
00
00
00
00
00
30
00
26℃
20℃