Hayward AquaRite LT Manual Del Usuario página 30

Ocultar thumbs Ver también para AquaRite LT:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 35
Electrolysis
1
OK
1
Electrolysis: Electrolysis function programming.
2
Level: Chlorine production (gr/h) required.
3
Cover: Closed cover safety activation.
Reduction: % of chlorine production when the cover is
closed (20% by default).
Salt concentration
1
OK
Setting the pH correction time
1
OK
1
Setting the pH correction time.
The chemical parameters of the water must be set
manually before the device is started up. If these
adjustments are not made in advance, unwanted AL3
alarms may be tripped.
2
Enter the password:
Caution: if the interval is too long, your pool may not be protected against acid overdoses and your equipment may be irreversibly damaged. Too short an interval may trip unwanted AL3
alarms.
Page 13 of 16
2
4
Boost (Super Chlorination): Filtration and
continuous production of chlorine for 24 hours
(maximum production level).
Automatic return to the filtration and production mode
programmed after the 24 hours.
2
2
+
-
3
Select the "Dos. pumps" menu.
4
Select the "pH pump" menu.
5
Normal mode:
- Delay: Time delay between detection of an incorrect
value and activation of the dosing pump.
6
Repetition mode:
- Pump On: pH pump operating time .
USE ONLY GENUINE REPLACEMENT PARTS
AquaRite LT
3
3
4
3
4
4
OK
5
Off Temp: Sets the temperature beyond which the salt
chlorinator will cut off. This temperature must be between
15°C and 10°C.
1
Salt concentration measurement.
2
Enter in the Salinity menu, use Enter to measure the
salt concentration for polarity 1, then for polarity 2. This
measurement can only be done manually. It will have to
be taken periodically.
3
Adjustment: Once the measurement has been taken,
you can adjust the salt level manually.
4
Display: Once the salt concentration has been
measured, it is displayed on the salt chlorination screen
and the main screen.
5
- Pump Off: pH pump downtime.
- Scaling: Determines the percentage injected by the
dosing pump (0% = no injection, 100% = maximum
dosing).
- The cycles are repeated until the selected setpoint value
is reached.
5
Rev. A

Publicidad

Tabla de contenido
loading

Tabla de contenido