Make Electrical Connection
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1. Disconnect power.
2. Remove terminal box cover.
3. Remove the knockout in the terminal box and install
a UL Listed or CSA approved 1/2" strain relief.
A. Knockout
B. Terminal box
C. Terminal box cover
4. Run home power supply cable through strain relief
into terminal box.
A
C
D
E
A. Home power supply cable
B. UL Listed or CSA
approved strain relief
C. Black wires
5. Use UL Listed wire connectors and connect
black wires (C) together.
10
A
B
C
B
F
D. UL Listed wire connectors
E. White wires
F. Green (or bare) and
yellow-green ground wires
6. Use UL Listed wire connectors and connect
white wires (E) together.
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal box.
Failure to do so can result in death or electrical shock.
7. Connect green (or bare) ground wire from home power
supply to yellow-green ground wire (F) in terminal box
using UL listed wire connectors.
8. Tighten strain-relief screw.
9. Install terminal box cover.
10. Check that all light bulbs are secure in their sockets.
11. Reconnect power.
Optional Power Cord Kit Installations
For optional power cord kit installations, follow the instructions
supplied with the power cord kit. See the "Assistance or
Service" section for information on ordering.
NOTE: Use only with range hood cord connection kits that have
been investigated and found acceptable for use with this model
range hood.
Install Vent Covers
1. When using both upper and lower vent covers, push lower
cover down onto hood and lift upper cover to ceiling and
install with two 4.2 x 8 mm screws.
B
A
A. Bracket
B. 4.2 x 8 mm screws
C. Vent cover
NOTE: For vented installations, the upper vent cover
may be reversed to hide slots.
C