PICKING UP SPILLS

The Hoover SteamVac spotter/carpet cleaner may be
used to pick up small liquid spills (1 gallon or less, never
to exceed 1/4 inch in depth) on carpet.
1.
Place floor nozzle with brushes turned to Spill Pick
Up in front of the spill. Pull the nozzle very slowly
over the spill initially with suction only. Repeat with
spray and suction. Although no cleaning solution
can completely remove all spots, they can be
treated by following the instructions provided by the
manufacturer of the carpet being cleaned.
WARNING! Do not use the cleaner to pick up
flammable or combustible liquids
or chemicals.
2. When finished cleaning, follow "After Cleaning"
instructions. (See Page 6)
STORAGE
Before storing:
• Empty solution tank and rinse thoroughly with clean
water.
DAILY
1.
Extension Cord and Plug – Check extension cord
and plug for any cuts or damage. If damaged,
discontinue use.
2. Motor – If there are unusual sounds or if poor
performance occurs, the motor should be inspected
immediately by the Uline service team.
3. Brush Indicator – When running the cleaner, check
to ensure that the brush indicator is spinning. If
brushes are not rotating and speed selector is
not set to "Spill Pick Up", inspect brushes for any
obstructions.
4. Rinse – Rinse out both tanks and filter after every use
and let them dry completely.
PAGE 7 OF 24
INSTRUCTIONS CONTINUED
LUBRICATION
The motor is equipped with bearings that contain
sufficient lubrication for the life of the motor. The
addition of lubricant could cause damage. Therefore,
do not add lubricant to motor bearings. The agitator
brushroll is equipped with two ball bearings that should
be lubricated periodically.

ROUTINE MAINTENANCE

WEEKLY
1. Clean Solution Tank – Inspect and clean out the
2. Recovery Tank – Inspect and clean out the dirty
3. Brushes – Inspect the brushes on the bottom of the
MONTHLY
1. Assembly – Check to ensure that no screws or parts
2. Brush Indicator – Examine Brush Indicator screen
• Replace empty solution tank and turn cleaner ON.
Squeeze trigger and push cleaner forward and
back several times to expel any solution remaining
in the cleaner's system. (Do not use cleaner on
wood floors.)
• Empty recovery tank and rinse thoroughly with clean
water.
• Allow brushes and underside of cleaner to air dry
thoroughly before storing cleaner on a carpeted or
wood surface.
NOTE: Do not store cleaner with a full solution
tank in place.
clean solution tank.
solution recovery tank.
cleaner. Pop out brushes and remove any hair or
debris that might be stuck in the bristles. Rinse them
clean and let dry.
have loosened up due to routine use. If necessary,
tighten up any loose screws.
and wipe off with a damp cloth if dust/dirt has
accumulated.