EXHAUSTING THE DRYER (cont.)
• DO NOT bend
or collapse
ducting. Use
elbows if turns
are necessary.
EXHAUST LENGTH
Using exhaust longer than specified length will:
• Increase the drying times and the energy cost.
• Reduce the dryer life.
• Accumulate lint, creating a potential fire
hazard.
The correct exhaust installation is YOUR
RESPONSIBILITY.
Problems due to incorrect installation are not
covered by the warranty.
FOR NORMAL VENT MODELS
RECOMMENDED MAXIMUM LENGTH
Recommended
4" DIA.
4"
No. of 90°
Rigid
Elbows
Metal
0
90 Feet
1
60 Feet
2
45 Feet
3
35 Feet
4
25 Feet
Installation Instructions
• DO cut duct as short
as possible and install
straight into wall.
EXHAUST LENGTH
Exhaust Hood Types
Use only for short
run installations
4" DIA.
4" DIA.
Rigid
Metal
60 Feet
45 Feet
35 Feet
25 Feet
15 Feet
• DO NOT use
excessive
exhaust
length. Cut
duct as short
as possible.
The MAXIMUM ALLOWABLE length of the exhaust
system depends upon the type of duct, number of
turns, the type of exhaust hood (wall cap) and all
conditions noted on the chart.
• Internal elbows added for side or bottom vent
conversions must be included in the total elbow count.
• Any elbow greater than 45° should be treated as a
90° elbow.
• Two 45° elbows will be treated like one 90° elbow.
• For every additional 90° elbow, reduce the allowable
vent system length by 10 feet.
• When calculating the total vent system length, you
must add all the straight portions and elbows of the
system (including the transition duct).
2-1/2"
No. of 90°
Elbows
0
1
2
3
4
5
8
• DO use elbows when
turns are necessary.
Elbows
• DO NOT
crush duct
against the
wall .
EXHAUST LENGTH
FOR LONG VENT MODELS
RECOMMENDED MAXIMUM LENGTH
Exhaust Hood Types
Recommended
4" DIA.
4" DIA.
4"
Rigid
Metal
150 Feet
135 Feet
125 Feet
115 Feet
105 Feet
95 Feet
• DO NOT
set dryer
on duct .
Use only for short
run installations
4" DIA.
2-1/2"
Rigid
Metal
125 Feet
115 Feet
105 Feet
95 Feet
85 Feet
75 Feet