3 Tighten the screw to fasten the push lever piece when
a suitable position is reached for a stapling test.
4 Connect the air hose.
ALWAYS WEAR EYE PROTECTOR.
Perform a stapling test.
5 DISCONNECT AIR HOSE FROM STAPLER.
6 Choose a suitable position for the push lever piece.
NOTE:
The information contained in this Manual is designed to assist you in the safe maintenance of the Stapler.
Some illustrations in this Manual may show details or attachments that di er from those on your own Stapler.
MAINTENANCE AND INSPECTION
Read section titled "SAFETY" (pages 4 – 8).
WARNING
Disconnect air hose and remove all staples
from Stapler when:
1) doing maintenance and inspection; and
2) clearing a jam.
1. Clearing a jam
Remove a jammed staple in the following order:
1 DISCONNECT AIR HOSE.
2 Remove all staples.
3 Release the lock lever and open the blade guide.
4 Remove the jammed staple with a slotted-head
screwdriver.
5 Close the blade guide and latch.
6 In case of frequent jam, contact a metabo HPT
authorized service center.
Lock lever
Blade
guide
3
000Book_N5008AC2_US_metabo.indb 17
000Book_N5008AC2_US_metabo.indb 17
MAINTENANCE
2. Storing
When not in use for an extended period, apply a thin
coat of the lubricant to the steel parts to avoid rust.
Do not store the Stapler in a cold weather
environment.
Keep the Stapler in a warm area.
When not in use, the Stapler should be stored in a
warm and dry place.
Keep out of reach of children.
3. WARNING LABEL
Do not use the Stapler with missing or damaged
WARNING LABEL.
A new WARNING LABEL is available from a
metabo HPT authorized service center.
Disconnect
1
air hose
4
Warning label