(1) DISCONNECT AIR HOSE FROM STAPLER.
REMOVE ALL STAPLES FROM STAPLER.
ALL SCREWS MUST BE TIGHTENED.
If any screws are loose, tighten them.
THE PUSH LEVER AND TRIGGER MUST MOVE
SMOOTHLY.
Trigger
Push
lever
(2) Adjust the air pressure to 70 psi (4.9 bar 5 kgf/cm
Connect the air hose.
Do not load any staples in the Stapler.
THE STAPLER MUST NOT LEAK AIR.
Hold the Stapler downward and pull the trigger.
THE STAPLER MUST NOT OPERATE.
Push lever
000Book_N5008AC2_US_metabo.indb 13
000Book_N5008AC2_US_metabo.indb 13
Do not connect
air hose
).
2
Pull trigger
(3) With fi nger o the trigger, depress the push lever
against the workpiece.
THE STAPLER MUST NOT OPERATE.
Do not pull trigger
Depress
push lever
(4) Without touching the trigger, depress the push lever
against the workpiece.
Pull the trigger.
THE STAPLER MUST OPERATE.
(5) With the Stapler o the workpiece, pull the trigger.
Depress the push lever against the workpiece.
THE STAPLER MUST OPERATE.
(6) If no abnormal operation is observed, you may load
staples in the Stapler.
Drive staples into the workpiece that is the same type
to be used in the actual application.
THE STAPLER MUST OPERATE PROPERLY.
ADJUSTING AIR PRESSURE
WARNING
Do not exceed 120 psi (8.3 bar 8.5 kgf/cm
Adjust the air pressure at recommended operating
pressure 70 – 120 psi (4.9 – 8.3 bar 5 – 8.5 kgf/cm
according to the length of staples and the hardness of
workpiece.
The correct air pressure is the lowest pressure which will
do the job. Using the Stapler at a higher than required air
pressure unnecessarily over stresses the Stapler.
English
).
2
)
2
13
2018/03/19 16:30:28
2018/03/19 16:30:28