Installation; Address Setting - Bosch ISP‑EMIL‑120 Manual De Instalación

Ocultar thumbs Ver también para ISP‑EMIL‑120:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 45
Expansion modules
A maximum of 2 IMS-RM relay modules can optionally be
installed in the expansion module housing (2 relays per relay
module, 2 switch contacts per relay), if the switched control
elements cannot be directly controlled from the expansion
module due to the high current requirement, or to enable zero-
potential switching.
A wall tamper contact can be installed, if required (optional). In
case of an EN 50131-3 Grade 3 compliant installation, the wall
tamper is mandatory.
3

Installation

1.
2.
3.
4.
4

Address setting

1.
2.
Notice!
The default setting is address "255" (all DIP switches are set to
"on").
Bosch Security Systems B.V.
Prepare the installation, refer to graphic 1 in chapter
Graphics, page 4 .
Open the wiring entry points, refer to graphic 2 in chapter
Graphics, page 4 .
Mount the lower part of the device and the screw for the
wall tamper contact (optional) to the wall, refer to graphic
3 in chapter Graphics, page 4 .
Mount the connection terminals, the relay module
(optional), and the wall tamper contact (optional), refer to
graphic 4 in chapter Graphics, page 4 .
To set the addresses of the expansion module, use a
suitable pointed implement to set the 8 DIP switches on
the connector board.
For the DIP switch settings (1 = on, 0 = off) for all
permissible addresses, refer to graphic 5, graphic 5.1, and
graphic 5.2 in chapter Graphics, page 4 .
Installation | en
2020-04 | 08 | F.01U.076.548
31

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Isp‑pcba‑emilIsp‑emil‑3rdp

Tabla de contenido