42
en | Technical data
Power output +12 V for external devices
Output voltage
Minimum output voltage
Maximum output voltage
Maximum output current in
mA
When connecting an arming device (e.g. NBS 10 / coded
arming device)
PL 1, 2, 5, 6 and S 1 - S 4
Primary line PL 3
Primary line PL 4
Terminal resistors for primary
line PL 3 blocklock in kΩ
Terminal resistors for primary
line PL 3 or PL 4 coded arming
device in kΩ
2020-04 | 08 | F.01U.076.548
Expansion modules
+12.5 V DC ± 5%
11.88
13.13
100, refer to Output current
dependencies
See above
Blocklock or coded
Coded arming device
For ISP-EMIL-120 and ISP-
PCBA-EMIL:
12.1 ±1% (armed)
12.1 II 3.92 ±1% (disarmed)
For ISP-EMIL-3RDP:
4.7 ±1% (armed)
4.7 II 4.7 ±1% (disarmed)
For ISP-EMIL-120 and ISP-
PCBA-EMIL:
12.1 ±1% (coded arming
device invalid)
12.1 II 3.92 ±1% (coded
arming device valid)
For ISP-EMIL-3RDP:
4.7 ±1% (coded arming device
invalid)
4.7 II 4.7 ±1% (coded arming
device valid)