Expansion modules
Element Description
8
9
10
5.4
Line-fed glass break detector
4
Element Description
1
2
5.5
IMS-RM relay module (optional)
4
Bosch Security Systems B.V.
Blocklock for primary line (wire color : 39 = black, 40
= blue)
Resistors (EOL 1 and EOL 2):
–
EOL 1 = 3k92 and EOL 2 = 12k1 for ISP-EMIL-120
and ISP-PCBA-EMIL
–
EOL 1 and EOL 2 = 4k7 for ISP-EMIL-3RDP
E.g. door contact
Resistor (EOL):
–
12k1 for ISP-EMIL-120 and ISP-PCBA-EMIL
–
4k7 for ISP-EMIL-3RDP
E.g. bolt contact
Resistor (EOL):
–
12k1 for ISP-EMIL-120 and ISP-PCBA-EMIL
–
4k7 for ISP-EMIL-3RDP
Refer to graphic 9 in chapter Graphics, page 4 .
Incoming and outgoing LSNs, can be exchanged.
4
Route the cable shield both ways.
A maximum of 20 glass break detectors can be
connected to a primary line PL 5 and PL 6 (VdS).
4
Loop in terminal resistance 12k1 after the last
detector.
A maximum of 3 detectors are supported in the event
of an alarm. Standby current: < 1 µA, max. alarm
current: 4 mA at 6 V.
Refer to graphic 10 in chapter Graphics, page 4 .
Connection | en
2020-04 | 08 | F.01U.076.548
35