Descargar Imprimir esta página

Flash Patterns - Ecco GOLD ECCOLED R65 Serie Instrucciones De Instalación Y Funcionamiento

Publicidad

Idiomas disponibles

Idiomas disponibles

Notes:
1.
Larger wires and tight connections will provide longer service life for components. For high current wires it is
highly recommended that terminal blocks or soldered connections be used with shrink tubing to protect the
connections. Do not use insulation displacement connectors (e.g., 3M Scotchlock type connectors).
2.
Route wiring using grommets and sealant when passing through compartment walls. Minimize the number of
splices to reduce voltage drop. High ambient temperatures (e.g., under-bonnet(hood)) will significantly reduce
the current carrying capacity of wires, fuses and circuit breakers. All wiring should conform to the minimum
wire size and other recommendations of the manufacturer and be protected from moving parts and hot surfac-
es. Looms, grommets, cable ties, and similar installation hardware should be used to anchor and protect all
wiring.
3.
Fuses or circuit breakers should be located as close to the power takeoff points as possible and properly sized
to protect the wiring and devices.
4.
Particular attention should be paid to the location and method of making electrical connections and splices to
protect these points from corrosion and loss of conductivity.
5.
Ground termination should only be made to substantial chassis components, preferably directly to the vehicle
battery.
6.
Circuit breakers are very sensitive to high temperatures and will "false trip" when mounted in hot environments
or operated close to their capacity.
Wires:
RED: POSITIVE (+VE)
BLACK: GND
YELLOW: Synchronisation - the patterns have Phase A and B. Connect all Yellow wires with units programmed in
Phase A and they will synchronise (up to 4 Beacons). Connect beacons programmed in Phase A and B and the units
will flash alternately.
BLUE: FLASH PATTERN SELECT- Momentarily connect to GND to increment flash pattern. Hold to GND for more
than 3 seconds to set pattern default

Flash Patterns:

Pattern No.
1
125 SFPM + 10 -5 (Single flashes per minute)
2
125 SFPM + 10 -5 (Single flashes per minute)
3
125 DFPM + 10 -5 (Double flashes per minute)
4
125 DFPM + 10 -5 (Double flashes per minute)
5
125 TFPM + 10 -5 (Triple flashes per minute)
6
125 TFPM + 10 -5 (Triple flashes per minute)
7
125 QFPM + 10 -5 (Quad flashes per minute)
8
125 QFPM + 10 -5 (Quad flashes per minute)
Specifications:
Voltage Supply (+VE): 10-32V DC
Current Consumption: 1.40A @ 12V DC
Peak Power: 17W @ 12V DC
Temperature Range: -20°C to +50°C
Description
Phase
A
ECE R65 Approved.
B
ECE R65 Approved.
A
ECE R65 Approved.Default pattern
B
ECE R65 Approved.
A
ECE R65 Approved.
B
ECE R65 Approved.
A
ECE R65 Approved.
B
ECE R65 Approved.
Other
Page 2 of 4

Publicidad

loading