Installation general

The recommended depth is described in the subsequent sections.
• Reinforcement should never be closer than at least 50 mm from stainless steel in the cast-coated pool constructions.
• Electrical installations >30V must not be placed within 500 mm distance from any stainless steel material.
• During installation works, stainless steel tools with clean contact surfaces should be used.
• In order to avoid scratches and stains, keep the items in their original packaging until installation.
• Be careful during installation, so as not to scratch the item.
• Avoid placing concentrated chemical dosages next to stainless steel details. Damage can occur in case of no pool circulation.
Electric installations
Observe local electrical regulations regarding location of the dosage connections.
The lighting must always be connected via a transformer protection 12V AC of the ring core type (see tables below) for correct
operation and maximum service life.
The supplied cord should always be used for LED connection.
If the external cable insulation or inner conductor of the lighting is damaged, replace it with a service technician or other
authorized person.
Recommendations
In order to get the desired function, the following recommendations for cables and lights connection should be followed.
Maximum and steady light is guaranteed only if the cable cross section is equal to or exceeds the values in the tables.
The cable lengths are calculated on account of the greatest possible power loss in the cables.
Min. cable length is 4 m.
The transformer's rated power must be equal to or greater than the rated power sum of the connected lamps.
Option 1.
This solution is preferable for new instal-
lations where channels location is not
complete.
All lights are connected directly to the
transformer with a separate cable
230VAC
4m cable, supplied for the lamp
A separate cable not included.
page 8 of 20
Option 1
Item no. Color
125840 Warm white
125841 Cold white
125842 RGB
Option 2.
Quantity of
Item no. Color
lamps
125840 Warmwhite
125841 Cold white
125842 RGB
Max cable length
12VAC
Max cable length / Cable cross section
1,5 mm
2,5 mm
2
77 m
129 m
77 m
129 m
62 m
103 m
Max cable length / Cable cross section
2,5 mm
4,0 mm
2
1
129 m
207 m
2
64 m
103 m
3
43 m
69 m
4
32 m
1
103 m
165 m
2
51 m
3
34 m
4
25 m
Option 2.
All lamps are connected to the transformer via power cable and
Wiring instructions Setup 2
coupling box
All lamps are connected to the transformer via 1 cable
230VAC
12VAC
4m cable, supplied for the lamp
A separate cable not included
page 10 of 20
4,0 mm
6,0 mm
2
2
207 m
207 m
165 m
6,0 mm
10,0 mm
2
2
311 m
155 m
103 m
51 m
77 m
248 m
82 m
124 m
55 m
82 m
40 m
62 m
12
ENGLISH
Max cable length
Kopplings-
box
Transformer power [VA]*
2
311 m
16
311 m
16
248 m
12
Transformer power [VA]*
2
519 m
16
259 m
32
173 m
64
129
128
414 m
12
207 m
24
138 m
36
103 m
48
Kopplings-
box