Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

CONTROL LEVER
The control lever (H106) can be set in three
positions (see below).
LOWER
NEUTRAL
ASCENT
ZEROING THE DISPLAY
You can press the ZERO key at any time
to zero the scale. This will usually only be
necessary when the pallet is empty. When
the zero point is obtained the display will
show zero.
The scale has an automatic rezeroing
function to account for minor drifting or
accumulation of material on the pallet.
However, you may need to press the ZERO
key to rezero the scale if small amounts of
weight are shown when the pallet is empty.
TARING
Zero the scale by pressing the ZERO key if
necessary. The zero indicator will be on.
Place a container on the pallet, display
shows weight.
Press the TARE key to tare the scale. The
weight that was displayed is stored as the
tare value and that value is subtracted
from the display. Zero shows on display.

OPERATION

LOWER:
Push lever up to lower
the forks
NEUTRAL
NEUTRAL:
to move the load
ASCENT
ASCENT:
Push lever down and
pump handle to raise
the forks.
The "GROSS" indicator will be off and "NET"
indicator on. As product is added, only
the weight of the product will be shown.
The scale could be tared a second time if
another type of product was to be added
to the first one. Again only the weight that is
added after taring will be displayed.
When the container is removed a negative
value will be shown. If the scale was tared
just before removing the container this
ASCENT
value is the gross weight of the container
plus all product that was removed. The zero
indicator will be on because the pallet is
back to the same condition it was when the
ZERO key was last pressed. Press TARE key
again to escape "NET" mode.
WEIGHING
Put the control lever in the LOWER position
and lower the truck to lowest position.
Press the ON/OFF key to turn the scale on.
After the indicator counts down, the display
will zero. Place the forks under the pallet.
While balancing load as evenly as possible,
put lever in "Ascent" position and pump
handle to raise load. Once stable indicator
shows, the accurate weight of the load is
displayed. (Total weight of pallet and the
goods)
NET/GROSS FUNCTION
This function is only available after TARE
function has been used. Pressing the N/G
button will toggle between total weight
(gross) on skid and weight after TARE
function was used (NET).
SELECTING WEIGHING UNITS
Press U key to select desired weighing units
(LBS or KG).