LaserLiner SuperCross-Laser 2P Manual Del Usuario página 9

Ocultar thumbs Ver también para SuperCross-Laser 2P:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 22
Preparing the calibration check:
It is possible for you to check the calibration of the laser. To do this, position the device midway between 2 walls,
which must be at least 5 metres apart. Switch the device on (Laser cross ON). The best calibration results are achie-
ved if the device is mounted on a tripod.
1.
A1
2.
Performing the calibration check:
3.
A1
4.
!
If points A2 and A3 are more than 5 mm / 10 m, the device is in need of calibration. Contact your authorised
dealer or else the UMAREX-Laserliner Service Department.
Checking the vertical line:
length on the wall, making sure that the bob can swing freely. Switch on the device and align the vertical laser to the
plumb line. The precision is within the specified tolerance if the deviation between the laser line and the plumb line is
not greater than ± 1.5 mm.
Checking the horizontal line:
Position the device about 5 m from a wall and switch on the cross laser. Mark point B
on the wall. Turn the laser cross approx. 2.5 m to the right and mark point C. Check
whether the horizontal line from point C is level with point B to within ± 2 mm.
Repeat the process by turning the laser to the left.
!
Regularly check the calibration before use, after transport and after extended periods of storage.
A2
A3
Position the device about 5 m from a wall. Fix a plumb bob with a line of 2.5 m
SuperCross-Laser 2P
1. Mark point A1 on the wall.
2. Turn the device through 180° and mark
point A2. You now have a horizontal
reference between points A1 and A2.
A2
3. Position the device as near as possible to
the wall at the height of point A1.
A2
4. Turn the device through 180° and mark
point A3. The difference between points
A2 and A3 is the tolerance.
A2
A3
2,5 m
B
C
09
EN

Publicidad

Tabla de contenido
loading

Tabla de contenido