EN
Mating
Mating Mode
Mating
Procedure
Navigation
End
point
End
point
Failed mating
Press and hold for 10 seconds to reset
the serial number stored in DRC1.
Standard readings
6
Before use, the DRC1 must be mated with the CDP unit .
This section describes how to mate the DRC1 with the dehumidifier .
1 . Insert batteries > Display flashes (if it does not flash, press the left button for 10 seconds and wait
until the display starts to flash)
The DRC1 will search for the dehumidifier for 2 minutes, during which time mating can be done:
- Press the up and down buttons on the CDP at the same time for 5 seconds
Note: this must be done while the DRC1 is searching for the dehumidifier .
If this procedure does not work:
Switch off the dehumidifier and wait for 5 seconds and then switch it on again .
2 . The dehumidifier will send a serial number to the DRC1 .
When mating is successful, the radio icon comes on .
3 . The dehumidifier will confirm connection by showing code "Conn"
onds
More than one remote control panel can be connected to the dehumidifier .
ENTER press and hold for 3 seconds to enter user menu setup
UP and DOWN buttons to navigate between icons .
LEFT and RIGHT buttons allows to change set points value 1press = 1unit
ENTER confirms new set point value and automatically switches to next icon/or exits the
menu
Press and hold RIGHT for 5 seconds to enter installer menu setup . ( Exit setup menu first)
When no button is pressed for 10 sec, the DRC1 exits the menu and returns to readings
screen
If mating fails
and
Reset DRC1 and repeat mating process .
Standard readings when connected:
-Stand by, RH and ºC scale
-Compressor active, dehumidifying symbol on
is shown in the display and the radio symbol flashes
for 3 sec-