BTL5-S1_ _(B)-M_ _ _ _-P-(SA244)-S32/KA_ _
Micropulse Linear Transducer in Profile Housing
EC Directive 89/336/EEC (EMC Directive) and EMC Law
Generic standards: EN 61000-6-4 (Emission), EN 61000-6-2 (Noise Immunity)
Emission tests: RF emission EN 55011 Group 1, Class A
Proper application
The BTL5 Micropulse transducer is
intended to be installed in a ma-
chine or system. Together with a
controller (PLC) or a master it com-
prises a position measuring system
and may only be used for this pur-
pose.
Installation
Ensure that no strong
electrical or magnetic
fields are present in the immedi-
ate vicinity of the transducer.
Any orientation is permitted.
Mount the transducer on a level
surface of the machine using the
mounting brackets and cylinder
head screws. Observe the recom-
mended spacing of the mounting
brackets.
The floating magnet is attached to
the moving member of the machine
using non-magnetizable screws
(stainless steel, brass, aluminum).
To ensure the accuracy of the trans-
ducer system, the moving member
must carry the magnet on a track
parallel to the transducer.
Permissible values for distance and
center offset are indicated in the
drawing.
Recommended installation:
Distance A = approx. 80 mm
Distance B = approx. 250 mm (be-
tween the individual clamps)
BTL5...P-S32
Mounting brackets with isolation bushings
and M5 × 22 cylinder head screws, DIN 912,
max. tightening torque 2 Nm
Wiring
System and control cabi-
net must be at the same
ground potential.
Pin
BTL5-S1_ _...S32
Interface signals
1
+Clk
2
+Data
3
–Clk
4
do not connect!
5
–Data
Supply voltage (external)
6
GND
7
+24 V
8
do not connect!
BKS Connector,
View of solder end
of connector body
BKS-S32M-00
or BKS-S33M-00
Colors
BTL5-S1_ _...-KA_ _
Interface signals
YE yellow
+Clk
PK ping
–Clk
GY gray
+Data
GN green
–Data
Supply voltage (external)
BU blue
GND
BN brown
+24 V
WH white
do not connect!
NL = Nominal length
Magnet
BTL5-P-3800-2
Startup
Observe all relevant safety regula-
tions!
Check connections: Components
can be damaged by improper con-
nections and overvoltage. Verify all
connections before applying power!
Turning on the system: Note that the
system may execute uncontrolled
movements when the transducer is
part of a closed-loop system whose
parameters have not yet been set.
Therefore make sure that no hazards
could result from these situations.
Check functionality: The functional-
ity of the transducer system and all its
associated components should be
regularly checked and recorded. In
particular, steps must be taken to
ensure that should the transducer
system become defective no hazards
to persons or property can result.
Fault conditions: When there is
evidence that the transducer sys-
tem is not operating properly, it
should be taken out of service and
guarded against unauthorized use.
User's Manual
A detailed user's manual can be ob-
tained on the Internet at
www.balluff.de using the link
Micropulse Transducers, User's
Manuals ..... E-mail requests can be
made to balluff@balluff.de
unusable area
not included
UL authorization
File No.
E227256