SIMPLEBUS REMOTE CAMERA MODULE ART. 1259C
This accessory in the Simplebus range allows modulation and transmission of
the video signal from 3 cameras which can be viewed cyclically on the monitor,
together with the image from the external unit.
Art. 1259C can be used in Simplebus Color Kit Simplebus Color systems (Art.
5714C, Art. 5714CI, Art. 4784, Art. 4784I, Art. 5814C, Art. 5814CI, Art. 6114C,
Art. 6114CI, 5914C, Art. 5724C) upstream of Art. 4888C.
Operation
With the monitor switched on, sequential switching of the TV cameras can be
activated from the video entry phone by means of function keys that depend on
the type of system and the programming of module 1259C using the 8-way
microswitch (S1) as described below. Sequential switching can also be activated
using a clean contact (C-NO) connected to the INA - GND input as per Diagram
SB2V/017PX. Sequential switching of the cameras is also possible in audio
mode. Each time the actuator pushbutton on the monitor or the manual contact
is pressed, a camera is activated in sequence as shown in Fig. 1: (hypothesis of
3 cameras connected, see MODE 1, 2, 3).
External unit
1st Camera
Fig. 1
Programming the number of cameras connected
The module has 3 coax video inputs to which the cameras must be connected,
occupying the terminals in the first free position starting from the bottom. Select
the number of cameras connected using switches 7 and 8 of selector S1, as
shown in Tab. 1.
DIP 7
0 Cameras
0
1 Camera
1
2 Cameras
0
3 Cameras
1
Tab. 1
1.GENERIC ACTUATOR MODE
NOTE: Before programming the module, see Tab. 3: Compatibility of 1259C.
Use the Generic Actuator function on a pushbutton of the
video entry phone to control module 1259C.
In this mode, with the video entry phone monitor
switched on, it is possible to cycle through all the
connected cameras by repeatedly pressing the generic
actuator pushbutton. Microswitch "S1" must be set as
shown in Fig. 2.
2.ACTUATOR WITH CODE MODE
NOTE: Before programming the module, see Tab. 3: Compatibility of 1259C.
In this mode, module 1259C can be controlled using an actuator with code
pushbutton. To activate the function, program the
pushbutton on the bracket and set selector "S1" as
shown in Tab. 2.
In this mode, with the video entry phone monitor
switched on, by repeatedly pressing the actuator with
code pushbutton, it is possible to cycle through ONLY the
cameras connected to module 1259C with the
corresponding address.
In the same system, it is possible to install up to 8 1259C
modules with 8 different codes.
MODE 4, 5
2nd Camera
3rd Camera
MODE 1, 2, 3
DIP 8
0
0
1
1
Fig. 2:
Setting for
generic actuator.
Fig. 3: Example of
Address setting on
Art. 1259C for
control using
actuator code 224.
DIP 1 DIP 2 DIP 3 DIP 4 DIP 5 DIP 6
1
0
0
0
0
0
1
0
1
0
0
0
1
0
0
1
0
0
1
0
1
1
0
0
1
0
0
0
1
0
1
0
1
0
1
0
1
0
0
1
1
0
1
0
1
1
1
0
Tab. 2
3.SIMPLEBUS COLOR KIT MODE
NOTE: Before programming the module, see Tab. 3: Compatibility of 1259C.
In this mode, the module Art.1259C may be controlled using the self-
ignition/video request pushbutton in the Simplebus Color Kit. In the event of self-
ignition, repeated pressing of the self-ignition/video
request pushbutton results in the toggling of images from
the external units installed as part of the system. When
audio mode is activated (by lifting the handset), repeated
pressing of the self-ignition button results in the toggling
of images from the external unit and the remote cameras
(connected to the module 1259C). Set selector "S1" as
shown in Fig. 4 to activate the function.
THE
THREE
OPERATING
MODES
ALTERNATIVES.
4.MODE WITH SWITCHBOARD 1998A
In parallel to one of the modes described above, it is possible to activate the
module by means of a Video Call from the switchboard. The "switchboard"
function is made available by connecting the INA-GND contact to the OUT-OUT
terminals of Art. 1998A , as shown in diagram SB2V/018PX.
NOTE: The remote camera module must be connected to the outgoing Bus
line from terminals LM-LM of the switchboard. Set the switchboard to
Video mode before making the call.
Each time a video call is made from the switchboard, the monitor will switch on
as soon as the handset is lifted, and the image displayed will be the one from
the first camera connected to Art. 1259C. At this point, each time a control
pushbutton is pressed (see previous modes) or each time the manual contact is
closed, a camera is activated in sequence as shown in Fig. 1 (hypothesis of 3
cameras connected, see MODE 4, 5).
5. MODE WITH EXTERNAL AUDIO UNIT ART. 1602
Previous modes 1, 2 and 3 may also be used in a system
which has an audio-only external unit, Art. 1602. When
setting the selected mode, DIP 1 of selector "S1" must be
configured as shown in Fig. 5 and
the external unit in video mode as
shown in Fig. 6. Every time a call
is received from the external unit
or when self-ignition occurs, the
monitor lights up and displays the
image coming from the first
camera connected to Art. 1259C.
At this point, each time a control pushbutton is pressed
(see previous modes) or each time the manual contact is
Fig. 6: Setting for
external audio unit
in video mode.

6.COMPATIBILITY TABLE

Generic actuator
mode
Compatibility
No 1256
with 1256
in function "E"
Compatibility
No other 1259C
with 1259C
Tab. 3: Compatibility of 1259C with 1256 or other 1259C.
FT SBC 05
Correspondence of 1259C address
actuator with code on bracket
Address
Actuator on bracket
1259C
code
0
220
1
221
2
222
3
223
4
224
5
225
6
226
7
227
Fig. 4:
Setting for SIMPLE-
BUS COLOR KIT.
DESCRIBED
ABOVE
ARE
Fig. 5:
Setting for use with
external audio unit
Art. 1602.
closed, a camera is activated in
sequence as shown in Fig. 1
(hypothesis
of
3
cameras
connected, see MODE 4, 5).
SIMPLEBUS
Actuator with code
COLOR
mode
KIT mode
No 1256 in function
Yes
"F" with codes
between 220 and 227
Only 1259C in mode
No other 1259C
2 with 8 separate
codes
5