Troubleshooting - Zoeller 2701 Manual De Instrucciones

Ocultar thumbs Ver también para 2701:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTALLATION INSTRUCTIONS
16. Install a basin cover and gasket (not included) on the
top of the basin. This will contain gases and odors,
prevent debris from falling into the basin, and prevent
personal injury.
17. Install a vent pipe (not included) according to local,
regional, or state codes to remove gases and odors.

TROUBLESHOOTING

Problem
Pump will not
1. Water level too low.
start or run.
2. Blown fuse or tripped circuit breaker.
3. Low line voltage.
4. Motor is defective.
5. Switch is defective.
6. Inlet screen clogged.
7. Switch is obstructed.
Possible Cause
10
16
Basin
cover
and
gasket
17
Corrective Action
1. Water must be at the appropriate level
to activate switch.
2. If blown, determine cause and then
either replace with properly sized fuse,
or reset breaker.
3. Contact an electrician.
4. Replace pump.
5. Replace switch.
6. Remove debris.
7. Remove obstruction to ensure free
motion of switch.
Vent
pipe

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido