American Standard Studio-S 4803100 Instrucciones De Instalación página 3

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

5
TEST INSTALLED FAUCET
• Move HANDLE (1) down into "off" position.
• With HANDLE (1) down in "off" position, pull HAND SPRAY (2) from SPOUT (3). SPRAY HOSE (4) should pull
approximately 2 feet and direct open SPRAY END (5) into sink.
• Operate handle up and down, in COLD and HOT positions, to flush water lines thoroughly.
• Check HAND SPRAY (2) operation:
2
4
5
6
SERVICE
If Faucet Drips Proceed As Follows:
• Turn VALVE in OFF position.
• If faucet drips, operate HANDLE several times from OFF to ON position.
Do not apply excessive force.
• FLOW CONTROL DEVICE may accumulate dirt. To remove the FLOW
CONTROL DEVICE, unthread SPRAY AND HOSE ASSEMBLY and
rinse clean FLOW CONTROL DEVICE.
Clogged CARTRIDGE outlets or inlets may cause reduced flow.
To clean, first turn off water supply then:
• Remove INDEX BUTTON (1), loosen HANDLE SCREW (2) and remove HANDLE (3).
• Unthread ESCUTCHEON CAP (4).
• Lift CARTRIDGE (6) off MANIFOLD (7) and remove CARTRIDGE SEALS (5).
• Clean MANIFOLD (7), CARTRIDGE (6) ports and SEALS (5).
• Place SEALS (5) into CARTRIDGE PORTS (6a).
• Place CARTRIDGE (6) onto MANIFOLD (7.
• Replace ESCUTCHEON CAP (4), HANDLE (3),
tighten HANDLE SCREW (1) and install
INDEX BUTTON (2).
•Test fitting.
7
CARE:
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
1
3
Spray and Hose
SPRAY OPERATION
• With FAUCET on, press TOGGLE BUTTON (6) on
SPRAY (3) to switch from stream to spray.
3
Flow Control
Device
Assembly
- 3 -
STREAM (AERATOR)
6
SPRAY
1
2
3
4
6
6a
5
7
M985010 (3/19)

Publicidad

Tabla de contenido
loading

Tabla de contenido