Installing the Interceptor

Overview

Interceptor load balances connections for in-path SteelHeads on the LAN-side of your network. SteelHeads
that are monitored by Interceptor are called peer neighbors.

1. Getting Started

Read the release notes for the appliance at https://support.riverbed.com. They contain important
information about this release.
Check your packing slip to make sure that you have all the necessary parts.
Make sure you have adequate space on a two-post or four-post 19-inch rack. The SteelHead Interceptor
requires 3U of rack space.
Make sure that the ambient temperature does not exceed 40ºC (104ºF) and the relative humidity does
not exceed 80 percent (noncondensing).
Make sure you have a standard Phillips screwdriver to install the appliance to a rack.
Gather the necessary information:
Hostname, IP address, netmask, DNS IP address, domain name, default gateway

2. Installing on a Rack

If your appliance requires rails, attach the rails to each side of the appliance. For details, see the Rack
Installation Guide.
Align the screw holes on the flanges with the screw holes on the rack.
Insert and tighten the screws on each side of the appliance.

3. Powering on the Interceptor

If your appliance has a master power switch, make sure it is in the off position (on the rear panel).
Getting Started Guide
Installing SteelHead Product Family Appliances (English)
19