Pentair BERKELEY BK4830 Manual De Instalación Y Operación página 2

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

4. Add lengths of pipe until ejector reaches correct depth
(ask your well driller for this information). As a guide, set
ejector 10 to 20 feet below lowest water level reached
while pump is running, but always at least five feet
above bottom of well.
5. To properly seat cup leathers, move assembly up and
down slightly after ejector is in position. Water pressure
in casing will seal the leathers.
6. See Figures 1 and 2 for casing adapter assembly and
installation for Models BK4830 and BK4850. See insert
sheet J80-59 for Model BK4840 Casing Adapter
installation.
important: Single pipe installations require galvanized
steel pipe nipples through the casing adapter; plastic at this
point will crush.
To Household
Water System
Drive (Small)
Pipe to Well
J216-13
Casing
Adapter
Well Casing
serves as
Drive Pipe
Suction Pipe
Not
Venturi
to
Scale
Nozzle
Ejector
figure 3 – bK4830 installed
Relief
Valve
Suction (Large)
Pipe from Well
Water
Level
with
Pump
Running
10 to
20 Feet
5 Feet
or more
2493 0796
7. With ejector set, slide casing adapter over top of well
casing. Tighten adapter bolts alternately to seat casing
adapter and form air-tight seal with well head. For Model
BK4830, also tighten long bolts to seal suction and drive
pipe where they pass through top of adapter.
8. bK4830: Install elbows and nipples or steel-to-plastic
adapters in casing adapter for horizontal pipe run. Use
pipe joint compound (with galvanized steel pipe) on
male threads.
bK4850: Peel backing off of gasket; stick gasket to top
of adapter. Bolt pump to adapter, making sure that faces
match. Align locating lugs on pump and casing adapter
or pump will not operate properly.
9. See pump owner's manual for pump hookup.
J216-21
Casing Adapter
(Use gasket
between adapter
and pump flange)
Well Casing
serves as
Drive Pipe
Suction
Pipe threads
into adapter
Venturi
Nozzle
Ejector
Cup
Leathers
figure 4 – bK4850 installed
2
Pump
bolts to
Casing
Adapter
flange
Tighten bolts
to seal adapter
to well casing
Water level
with pump
running
Not
to
Scale
10 to 20 Feet
5 Feet
or more
2494 0796