Description
Single pipe ejector packages (Models BK4830, BK4840 and
BK4850) include a 2" packer type ejector, seals, hardware,
and an assortment of nozzles and venturis to suit your well
conditions. Use Model BK4850 with vertical jet pumps on
any 2" single pipe well installation. Use Model BK4840 with
any deep well or convertible jet pump on any 2" single pipe
well installation.* Use Model BK4830 with any convertible or
deep well jet pump (single or multi-stage) on any 2" single
pipe well installation.
* See insert sheet J80-59 for Horizontal Casing Adapter
installation instructions.
General safety information
Follow safety instructions in your pump owner's manual.
BE SURE pump is turned off before installing the deep well
ejector.
california proposition 65 Warning
This product and related accessories contain
chemicals known to the State of California to cause cancer,
birth defects or other reproductive harm.
A
figure 1 – pkg bK4830 casing adapter assembly
(part no. J216-13)
293 WRIGHT STREET, DELAVAN, WI 53115 WWW.BERKELEYPUMPS.COM
PH: 888-782-7483
© 2013 Pentair, Ltd. All Rights Reserved.
InstallatIon, operatIon, & parts Manual
B
Tighten
bolts to
clamp
pipe and
casing
C
Adapter
exploded
2492 0796
Models BK4830, BK4840, BK4850
Deep Well 2" Single Pipe
assembly
1. Use only one nozzle (Figure 5, Ref. No. 2) and one
venturi (Ref. No. 1) with any installation.
important: Consult pump owner's manual to determine
correct nozzle and venturi to use.
2. Use 5/8" deep-well socket to screw nozzle in to
recessed hole in top of ejector body (Ref. No. 3).
Tighten securely.
3. Screw venturi into top of ejector body right over nozzle.
Do not overtighten.
installation
important: Single pipe installations require galvanized
steel pipe in addition to materials in ejector package.
1. Place ejector in a pail of water for at least two hours to
soak the cup leathers.
2. After leathers are thoroughly soaked, connect ejector to
first length of pipe. Use pipe joint compound sparingly
on male threads.
3. Lower pipe into well casing. Use special turned cou-
plings (included with ejector package) and use pipe joint
compound sparingly on male threads. As pipe is added,
hold it securely and fill it with water to be sure foot valve
and connectors do not leak.
figure 2 – pkg bK4850 casing adapter assembly
(part no. J216-21)
Ejector Packages
A
Adapter
exploded
B
Adapter
installed
2495 0796
BE550 (Rev. 02/25/13)