Dansk
English
© Danfoss | DCS (sw) | 2016.05
Elektriske specifikationer
Parameter
Stepmotortype
Step mode
Fasemodstand
Faseinduktans
Holdestrøm
Trinvinkel
Nominel spænding
Fasestrøm
Maks. total effekt
Trinhastighed
Total trin
Samlet gennemløbstid
Referenceposition
Elektrisk tilslutning
Electrical specifications
Parameter
Stepper motor type
Step mode
Phase resistance
Phase inductance
Holding current
Step angle
Nominal voltage
Phase current
Max. total power
Step rate
Total steps
Full travel time
Reference position
Electrical connection
CCM
Bipolar – permanent magnet
2-faset fuldt step
52Ω ±10%
85 mH
Afhænger af applikationen.
Fuld strøm tilladt (100 % driftscyklus)
7.5° (motor),
0.9° (ledeskrue),
Udvekslingsforhold 8,5:1. (38/13)
(Konstant spændingsomformer) 12 V DC -4 % +15 %, 150 trin/sek.
(Ved at anvende jævnstrømsfrekvensomformer) 100 mA RMS -4 % +15 %,
Spændings-/strømomformer: 5,5/1,3 W (UL:NEC-klasse 2)
150 trin/sek. (konstant spændingsomformer)
0-300 trin/sek. 300 anbefales (jævnstrømsfrekvensomformer)
CCM 10, 20 & 30:
2625 [+160 / -0] trin
CCM 40:
3530 [+160 / -0] trin
CCM 10, 20 & 30:
17/8,5 sek. (spænding/strøm)
CCM 40:
23/11,5 sek. (spænding/strøm)
Overstyring mod den fulde lukkeposition
4 tråd 0,5 mm
0,3 m langt kabel
2
CCM
Bi-polar - permanent magnet
2 phase full step
52Ω ±10%
85 mH
Depends on application.
Full current allowed (100% duty cycle)
7.5° (motor),
0.9° (lead screw),
Gearing ration 8.5:1. (38/13)
:1
2
(Constant voltage drive) 12 V dc -4% +15%, 150 steps/sec.
(Using chopper drive) 100 mA RMS -4% +15%,
Voltage / current drive: 5.5 / 1.3 W (UL: NEC class 2)
150 steps/sec. (constant voltage drive)
0-300 steps/sec. 300 recommended (chopper current drive)
CCM 10, 20 & 30:
2625 [+160 / -0] steps
CCM 40:
3530 [+160 / -0] steps
CCM 10, 20 & 30:
17 / 8.5 sec. (voltage / current)
CCM 40:
23 / 11.5 sec. (voltage / current)
Overdriving against the full close position
4 wire 0.5 mm
2
(0.02 in
2
), 0.3 m (1 ft) long cable
:1
2
DKRCI.PI.VK1.A4.53 | 520H11123 | 4