Technical Data - HK Audio ACTOR AT 112 A Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

8 Technical Data

AT 112 A:
Inputs / Outputs:
Input:
Input impedance:
Sensitivity:
Peak input level:
Parallel Out L/ R:
Speakers:
Power output:
Sound pressure level 1W/1m:
Max. sound pressure level / 1m:
Directivity:
Frequency response:
Crossover frequencies:
Low-cut:
Weight:
Dimensions (WxHxD:
AT 115 SUB A:
Inputs / Outputs:
Input:
Input impedance:
Sensitivity:
Peak input level:
Parallel Out L/ R:
Speaker:
Power output:
Sound pressure level 1W/1m: ^
Max. sound pressure level / 1m:
Frequency response:
Crossover:
Weight:
Dimensions (WxHxD):
General electrical data:
Protection class 1
Mains voltage 230V:
Mains voltage 117V:
Mains voltage 100V:
Max. current consumption:
Max. power consumption:
Mains voltage range:
Ambient temperature range:
Internal fuses:
Line In L/ R: XLR female ( 1 = ground; 2 = +; 3 = - )
electronically balanced & floating
47 kΩ
0 dB
+24 dB
XLR male ( 1 = ground; 2 = +; 3 = - )
1x 12" B&C Speaker, 1x 1" BMS driver, 60° x 40° horn
400 watts (active)
106 dB (half-space)
129 dB @ 10% THD (half-space)
Horizontal: ± 30° ; 2kHz - 20 kHz
Vertical: ± 20° ; 3kHz - 20 kHz
100 Hz - 20 kHz; ± 3 dB
12"/1": 1.3 kHz, 12 dB/octave
(Sat/Full-range switch), 100 Hz, 24 dB/octave
29 kg / 63.8 lbs.
40 x 65 x 42 cm - 15 3/4" x 25 5/8" x 16 1/2"
Line In L/ R: XLR female ( 1 = ground; 2 = +; 3 = - )
electronically balanced & floating
47 kΩ
0 dB
+24 dB
XLR male ( 1 = ground; 2 = +; 3 = - )
1x 15" HK AUDIO custom
400 watts (active)
104 dB (half-space)
126 dB @ 10% THD (half-space)
40 Hz - 130 Hz
130 Hz, 24 dB/octave
35 kg / 77 lbs.
48 x 65 x 64 cm - 18 7/8" x 25 5/8" x 25 1/8" incl. wheels
(protectively grounded/earthed)
Power fuse T 2A (AT 112 A and AT 115 Sub A)
Power fuse T 4A or SB 4A (AT 112 A &. AT 115 Sub A)
Power fuse T 4A (AT 112 A and AT 115 Sub A)
2.7A @230 volts
630 VA
+/- 10%
-10°C to + 60°C
4x T 4A's
Covers are available separately for the ACTOR system's
subwoofer and top unit.