10. Assembly Instructions
Warning!
Use the fitting only with the grit filters specified.
Failure to observe can result in an increased bacterial load in drinking water and
cause a health risk or even risk of death.
☞
Important!
Before installing, flush the pipes in compliance with DIN 1988.
☞
Do not shorten the connector hoses located at the fitting.
☞
Connect the fitting only to the original plug-in power supply. Connect the plug-in
power supply only to a socket carrying 230 V/50 Hz.
10.1 Install the fitting (a) on the washbasin (b).
☞
Important!
Observe the range settings when installing on a stainless steel washbasin
Chapter
12.
☞
The corner valve (c) must be provided by the customer.
10.2 Screw the connecting hose (d) on to the corner valve.
10.3 Insert the plug-in power supply into the socket.
10.4 Connect the line between the fitting and the power supply.
11. Function
11.1 Allow your hand to approach the sensor.
• Water flows.
11.2 Remove your hand from the sensor.
• Water flow stops automatically after a set flow duration.
☞
The range of the sensor and the flow duration can be adjusted with the optional
remote control (FAR Order No. 2000101087).
☞
Important!
Reflecting surfaces can influence the sensor. There is a risk of having permanent
reflections. ((see
"Auto-flush" function
Caution!
When the "Auto flush" function is used, the flow of water must be ensured.
• The "Auto-flush" function ensures that forced flushing takes place to exchange the
water in the tap lines after 24 or 72 hours of non-use.
• The "Auto-flush" function can only be switched on with the optional remote control
(FAR-Order-No. 2000101087).
• This function is switched off at the factory.
6
Chapter 12.
for adjusting the sensor range).
info@hygiene-shop.eu - www.hygiene-shop.eu