Scope Of Delivery; Dimensions; Installation Example; Assembly Instructions - Franke AQUA502 Instrucciones De Montaje

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 19
8.

Scope of Delivery

Item
Description
1
WC flusher with solenoid valve unit
2
Electronic module M2
3
Adapter cable
4
Cover plate
5
Frame
6
Fixing set
Installation and Operating Instruc-
tions
9.

Dimensions

10. Installation Example

11. Assembly Instructions

Warning!
• Operate the product only with safety extra low voltage (SELV). Do not earth the
components.
• The power supply (not included in the scope of delivery, see Accessories,
Chapter
18) must be set up outside of the wet area, in a separate room.
• Secure the electric connection with an earth leakage circuit breaker (RCD).
Failure to observe can mean risk of death or material damage, e. g. from electric
shock or fire.
The system line (not included in scope of delivery) for connecting the power supply
to the fittings must be installed in a conduit (to be supplied by customer) and looped
through.
Important!
Before installing, flush the pipes in compliance with DIN 1988.
11.1 Remove the shell protection.
11.2 Close the water volume regulators with a hollow hexagon wrench.
a: closed
b: open
- 6 -

Publicidad

Tabla de contenido
loading

Tabla de contenido