Center Line
2. Install Electrical Service
DANGER: Risk of electrical shock. Connect only to a
properly-grounded, grounding-type receptacle which is protected
by a Ground-Fault Circuit-Interrupter (GFCI).
A licensed electrician should install a properly-grounded,
grounding-type receptacle which is protected by a Class A
Ground-Fault Circuit-Interrupter.
The receptacle should be located 6" (15.2cm) above the floor line,
and 2-3/4" (7cm) to the right of the closet flange centerline.
The toilet electrical cord is 36" (91.4cm) long.
1021801-2-A
GFCI-Protected Receptacle
6" (15.2cm)
2-3/4" (7cm)