If the phase rotation order is indirect, LED L1 to L3 lights up.
NB : The voltage detection is still active during this test.
Characteristics and field of use:
230V < U < 690V
Frequency: 50 Hz and 60 Hz (± 5 %)

8. GENERAL CHARACTERISTICS

Power supply
1 battery 9 V 6F22, 6LR61 or NEDA 1604
Battery life:
6000 measurements lasting 10 seconds (with 9 V alkaline
batteries)
3000 measurements lasting 10 seconds(with 9 V saline battery
6F22 as supplied)
Buzzer:
Series of 2 beeps for each change of range.
2 kHz continuous for continuity
Duration / Operating cycles:
690 VAC : unlimited operation
Climatic conditions:
Reference: 23°C ± 3°C
Use:
- temperature: -10°C to + 55°C
- relative humidity: < 96 % RH
- altitude: up to 2000 m
Storage:
- temperature: -10°C to 55°C (without battery)
Dimensions / Weight:
163 x 63.6 x 40mm / 210 g (battery included)
9. CONFORMITY WITH INTERNATIONAL STANDARDS.
Voltage detector (as per 61243-3 - Ed.10/98 and
NF EN 61010-1 2001 600 V CAT III)
Electrical safety
Device as per NF EN 61010-1 : 2001
- Degree of pollution : 2
- Measurement category III for assigned voltage 600 V
22
Page 22
Device as per NF EN 61243-3:
- Class B
- Type: outdoor
Cords as per NF EN 61010-1 : 2002
- Degree of pollution : 2
- Measurement category III for assigned voltage 600 V
Electric shock
(test as per IEC 1000-4-5)
6 kV in differentail mode for function voltmeter class B.
Electromagnetic compatibility
EN 61326-1/A2 : 2001 criterion B
Mechanical protection
Casing protection degree
(as per NF EN 60529/A1 : 2000)
- IP 65 for casing
- IP 20 for probes
NB : The casing is protected from the penetration of dust and water
jets.
In spite of this protection it is not advisable to use the multimeter
in the rain.

10. GUARANTEE

Our guarantee applies unless stipulated otherwise for 24 months
after the date of equipment provision for the casing and
its electronics.
The mechanical ruggedness of the casing and its electronics enables
us to guarantee its operation for a height of fall of 2 m.
The probes and battery are not concerned by this guarantee.

11. MAINTENANCE

For maintenance, use only the specified spare parts. The
manufacturer cannot be held responsible for any accidents occurring
after a repair carried out outside of his after sales department or of
approved repairers.
Battery replacement
For your safety never open the multimeter before disconnecting it for
any source of electricity.
Remove the captive screw attaching the battery compartment
cover and open the cover.
23