VOLTAGE FUNCTION TEST
Implementation:
Check the operation of the device on a known voltage value: on
a 9 V battery for instance and for a voltage network that is
known.
Result:
The expected value must be read on the display.
If the self-test is incorrect, change the battery or proced with
repairs.
4. VOLTAGE MEASUREMENT AUTO AC/DC, POLARITY
Always run a self-test before using your multimeter.
Never use it if the self-test is incorrect.
Implementation:
Place the two test probes on the circuit to be tested.
Voltage measurement:
The presence of a voltage in excess of 1 V AC or DC on the
circuit ensures the automatic lighting of the display and the back-
lighting as well as the emission of an audible signal by the
buzzer for each change of ranges.
Characteristics and field of use:
• Voltage detection: 1 V < U < 690 V between phases (600 V with
respect to ground)
• Frequency: DC, 50...60 Hz
• High impedance does not switch the differential circuit breaker.
• Max. current at 690 V: Is ≤ 3.5mA peak
Automatic implentation for a voltage between phases in excess
of 1 V.
Automatic recognition of DC and and AC for a voltage between
terminals in excess of 1 V.
Automatic selection of the range.
Hold function: freezes the display.
Immediate auto shut-off, on after 10 seconds in HOLD function,
once the measurement has been disconnected
NB 1: The HOLD function does not cancel the auto-off.
NB 2: Press the auto ON/OFF key to manually push manually
switch ON
18
Page 18

TECHNICAL SPECIFICATIONS

General information:
Only the values assigned with tolerances or the announced limits are
representative of guaranteed limits. Values without a tolerance are
for information only.
Characteristics:
Typical accuracy is ± [% of the reading (L) + number of
representation units (digits or D)] under the reference conditions (see
Appendix).
DC voltage (Autorange)
Range
Measurement
2 V
0.2 V à 1.999 V
20 V
2 V à 19.99 V
200 V
20 V à 199.9 V
2000 V
200 V à 690 V
Protection from overloads: 750 Vrms for 20 s.
AC voltage (Autorange)
Range
Measurement
2 V
0.5 V to 1.999 V
20 V
2 V to 19.99 V
200 V
20 V to 199.9 V
2000 V
200 V to 690 V
Protection from overloads: 750 Vrms for 20 s.
Influencing conditions
Influencing magnitude
from -10°C to +18°C
from +28°C to +55°C
Relative humidity :
from 20% to 96%
Voltage
(power supply) :
from 6.5V to 9.75V
Resolution
Typical precision
0.001 V
1 % ± 2 pts
0.01 V
1,2 % ± 2 pts
0.1 V
1,2 % ± 3 pts
1 V
1,2 % ± 3 pts
Frequency
Typical precision
Resolution
50 to 60 Hz
2% ± 2 pts
0.001 V
50 to 60 Hz
2% ± 2 pts
0.01 V
50 to 60 Hz
2% ± 2 pts
0.1 V
50 to 60 Hz
2% ± 2 pts
1 V
Measurement influence
VDC : 0.2% / 10°C
VAC : 0.5% / 10°C
VDC : 0.75% / 10°C
VAC : 2% / 10°C
No influence
No influence DDT
Continuity influence
Phase identification -
Identification variation
19