SN2013, SN2033 - Infrared
1
Install Unit
A
Remove Access panel and with
the help of another person, place
unit in position against both walls .
B
Ensure unit is level, shimming floor unit if
necessary . Mark the wall anchor locations .
2
Connect Water Supply to Valve Assembly
WARNING! Do not turn on water until
Step 4 is completed!
Connect stops to hot and cold water supply .
A
Connect one end of each supply hose to a
stop and the other end to the hot and cold
inlets of the Navigator TMV .
6
Rough-in of plumbing lines, wall braces
and electrical box must be completed
before unit can be properly installed.
Water Supply
Gang Valve
Assembly
OPTIONAL TEMPERED LINE CONNECTION: Connect one
B
end of the supply hose to the stop and the other end to the
tempered line adapter in the gang valve assembly .
8/21/2017
Install suitable wall anchors (supplied
C
by installer) for 3/8" bolts at the marked
locations . Secure unit to wall .
Red Tube
(to Aerator)
Green Tube
(to Aerator)
Black Tube
(to Aerator)
Navigator TMV
(S01-526)
Cold Supply Inlet
Bradley • 215-923 Rev. M; ECN 17-00-002
Water Supply
Gang Valve
Assembly
OPTIONAL
Tempered
Line Adapter
Assembly
(S39-804)
Braided
Hose
Stop Valve
Hot Supply Inlet
Installation