Twilight setting (Fig� 6�1)
The chosen sensor response threshold is infinitely adjustable from approx. 2-1000 lux.
Control dial set to
means twilight mode at approx. 2 lux.
Control dial set to
means daylight operation / independent of ambient light level.
Teach mode
The control must be set to
at the level of light at which you want the sensor to
respond to movement from now on. The level of ambient brightness measured in this
way will be saved after 10 seconds.
Dazzle guard
This product is equipped with an integrated dazzle guard. If blinded by extraneous light,
this puts the sensor into a brightness-related evaluation mode for 60 s.
(➔ "11� Troubleshooting")
Constant light
Provides a constant level of brightness. Detector measures the prevailing level of day-
light and activates sufficient artificial light to achieve the required level of brightness. As
daylight changes, the added artificial lighting component is adjusted. In addition to the
daylight component, artificial light is also switched ON and OFF in relation to whether or
not persons are present.
Constant-lighting control can be activated and deactivated via RC8 remote control and
Smart Remote.
Presence detector switch-off logic
The load connected is switched OFF once the selected light level is exceeded.
Time setting (Fig� 6�1)
The time you want the connected lamp to stay ON for is infinitely adjustable from ap-
prox. 5 sec to a maximum of 15 min. Any movement detected before this time elapses
will restart the timer.
LED function
– Normal mode: LED stays OFF
– Test mode: LED lights up on detecting movement
– Remote control: LED flashes approx. 10 times per second
– Permanently ON/OFF: LED lit
7� Accessories (optional)
User remote control RC5 EAN
Additional functions RC5
– Light ON/OFF 4 h
– User reset
– 100 h burn in, 4 h light ON press for ≥ 5 s
30
– DIM1 - / DIM1 +
– Save scene 1
– Activate scene 1
– Save scene 2
– Activate scene 2
Service remote control RC8 EAN
Additional functions RC8
– Time setting CH1
– Test / normal mode
– Twilight setting
– Night-time operation
– Daylight operation
– Teach-IN
– Reset
– Basic brightness: 1 = 10% ... 5 = 50%, press for ≥ 5 s
Smart Remote EAN
– Replaces remote controls RC5 and RC8
– Control via smartphone or tablet
– Load appropriate app and connect via Bluetooth
– Identify the sensors and read parameters
Additional functions Smart Remote
– Light-level setting: teach, 2-1000 lux
– Main light level: 50% - 100%
– Initial state: behaviour after applying the light ON/OFF supply voltage
– Sensor
– Time setting 5 s - 60 min
– Basic light level: ON, OFF, 10 - 30 min, night
– Basic brightness level: 10% - 50%
– Burn in
LED function
– Normal mode: LED stays OFF
– Test mode: LED lights up on detecting movement
– Remote control: LED flashes at approx. 10 Hz
– Permanently ON/OFF: LED ON
Detailed descriptions are provided in the operating instructions for the particular
remote control.
8� Operation / maintenance
The infrared sensor can be used for switching light ON and OFF automatically. The unit
is not suitable for burglar alarm systems as it is not tamperproof in the manner pre-
scribed for such systems. Weather conditions may affect the way the motion detector
31