STEINEL PROFESSIONAL IS 3360 Manual De Instrucciones página 18

Ocultar thumbs Ver también para IS 3360:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 34
IS 3180
IS 3360 MX
Manual override
(permanent light)
IP rating
Surface-mounted: IP 54 Concealed: IP 20
Temperature
zone
12� Troubleshooting
Malfunction
Cause
No power at the sensor
n Fuse faulty,
not switched ON,
break in wiring
n Short circuit
Sensor will not switch ON
n Twilight setting in night
mode during daytime
operation
n Bulb faulty
n Mains power switch
OFF
n Fuse faulty
n Detection zone not
properly targeted
Sensor will not switch OFF
n Continuous movement
in the detection zone
n Light being operated
is located in detection
zone and keeps switch-
ing ON as a result of
temperature change
n Light being operated
is in manual override
mode (LED ON)
Sensor keeps switching
n Light being operated
ON/OFF
is located in detection
zone
n Animals moving in
the detection zone
IS 3360
IS 345
IS 345 MX
selectable (4 h)
-20°C to +50°C
Remedy
n New fuse, turn ON
power switch, check
wiring with voltage tester
n Check connections
n Adjust setting
n Change bulb
n Switch ON
n Fit new fuse, check
connection if necessary
n Readjust
n Check zone, adjust or fit
shrouds if necessary
n Change detection zone
or fit shrouds
n Deactivate manual
override
n Change zone or
fit shrouds,
increase distance
n Change detection zone
or fit shrouds
34
Malfunction
Cause
Sensor reach
n Differing ambient
change
temperatures
Sensor responds
n Wind is moving trees
when it should not
and bushes in the
detection zone
n Cars on the road are
being detected
n Sunlight is shining
on the lens
n Sudden change in
temperature caused
by weather (wind, rain,
snow) or air discharged
from fans, open windows
n Dazzle guard active
n Sensor near Wi-Fi
or other wireless
communication source
Remedy
n Use shrouds to define
detection zone precisely
n Change detection zone
n Change detection zone
n Mount sensor in a
sheltered place or
change detection zone
n Change detection zone,
mount in a different
place
n Switch OFF manually
via button/switch
n No movement detected
within the selected
stay-ON time + 60 sec
(dazzle guard)
n Install at least 2 m
away from the wireless
communication source
35

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Is 3360 mxIs 345Is 345 mxIs 3180

Tabla de contenido